| * Licensed to the Apache Software Foundation (ASF) under one |
| * or more contributor license agreements. See the NOTICE file |
| * distributed with this work for additional information |
| * regarding copyright ownership. The ASF licenses this file |
| * to you under the Apache License, Version 2.0 (the |
| * "License"); you may not use this file except in compliance |
| * with the License. You may obtain a copy of the License at |
| * |
| * https://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, |
| * software distributed under the License is distributed on an |
| * "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY |
| * KIND, either express or implied. See the License for the |
| * specific language governing permissions and limitations |
| * under the License. |
| */ |
| |
| package model |
| |
| import ( |
| "context" |
| stdErrors "errors" |
| "fmt" |
| |
| "github.com/pkg/errors" |
| "github.com/rs/zerolog" |
| |
| . "github.com/apache/plc4x/plc4go/spi/codegen/fields" |
| . "github.com/apache/plc4x/plc4go/spi/codegen/io" |
| "github.com/apache/plc4x/plc4go/spi/utils" |
| ) |
| |
| // Code generated by code-generation. DO NOT EDIT. |
| |
| // Constant values. |
| const ModbusPDUReadDeviceIdentificationResponse_MEITYPE uint8 = 0x0E |
| |
| // ModbusPDUReadDeviceIdentificationResponse is the corresponding interface of ModbusPDUReadDeviceIdentificationResponse |
| type ModbusPDUReadDeviceIdentificationResponse interface { |
| fmt.Stringer |
| utils.LengthAware |
| utils.Serializable |
| utils.Copyable |
| ModbusPDU |
| // GetLevel returns Level (property field) |
| GetLevel() ModbusDeviceInformationLevel |
| // GetIndividualAccess returns IndividualAccess (property field) |
| GetIndividualAccess() bool |
| // GetConformityLevel returns ConformityLevel (property field) |
| GetConformityLevel() ModbusDeviceInformationConformityLevel |
| // GetMoreFollows returns MoreFollows (property field) |
| GetMoreFollows() ModbusDeviceInformationMoreFollows |
| // GetNextObjectId returns NextObjectId (property field) |
| GetNextObjectId() uint8 |
| // GetObjects returns Objects (property field) |
| GetObjects() []ModbusDeviceInformationObject |
| // IsModbusPDUReadDeviceIdentificationResponse is a marker method to prevent unintentional type checks (interfaces of same signature) |
| IsModbusPDUReadDeviceIdentificationResponse() |
| // CreateBuilder creates a ModbusPDUReadDeviceIdentificationResponseBuilder |
| CreateModbusPDUReadDeviceIdentificationResponseBuilder() ModbusPDUReadDeviceIdentificationResponseBuilder |
| } |
| |
| // _ModbusPDUReadDeviceIdentificationResponse is the data-structure of this message |
| type _ModbusPDUReadDeviceIdentificationResponse struct { |
| ModbusPDUContract |
| Level ModbusDeviceInformationLevel |
| IndividualAccess bool |
| ConformityLevel ModbusDeviceInformationConformityLevel |
| MoreFollows ModbusDeviceInformationMoreFollows |
| NextObjectId uint8 |
| Objects []ModbusDeviceInformationObject |
| } |
| |
| var _ ModbusPDUReadDeviceIdentificationResponse = (*_ModbusPDUReadDeviceIdentificationResponse)(nil) |
| var _ ModbusPDURequirements = (*_ModbusPDUReadDeviceIdentificationResponse)(nil) |
| |
| // NewModbusPDUReadDeviceIdentificationResponse factory function for _ModbusPDUReadDeviceIdentificationResponse |
| func NewModbusPDUReadDeviceIdentificationResponse(level ModbusDeviceInformationLevel, individualAccess bool, conformityLevel ModbusDeviceInformationConformityLevel, moreFollows ModbusDeviceInformationMoreFollows, nextObjectId uint8, objects []ModbusDeviceInformationObject) *_ModbusPDUReadDeviceIdentificationResponse { |
| _result := &_ModbusPDUReadDeviceIdentificationResponse{ |
| ModbusPDUContract: NewModbusPDU(), |
| Level: level, |
| IndividualAccess: individualAccess, |
| ConformityLevel: conformityLevel, |
| MoreFollows: moreFollows, |
| NextObjectId: nextObjectId, |
| Objects: objects, |
| } |
| _result.ModbusPDUContract.(*_ModbusPDU)._SubType = _result |
| return _result |
| } |
| |
| /////////////////////////////////////////////////////////// |
| /////////////////////////////////////////////////////////// |
| /////////////////////// Builder |
| /////////////////////// |
| |
| // ModbusPDUReadDeviceIdentificationResponseBuilder is a builder for ModbusPDUReadDeviceIdentificationResponse |
| type ModbusPDUReadDeviceIdentificationResponseBuilder interface { |
| utils.Copyable |
| // WithMandatoryFields adds all mandatory fields (convenience for using multiple builder calls) |
| WithMandatoryFields(level ModbusDeviceInformationLevel, individualAccess bool, conformityLevel ModbusDeviceInformationConformityLevel, moreFollows ModbusDeviceInformationMoreFollows, nextObjectId uint8, objects []ModbusDeviceInformationObject) ModbusPDUReadDeviceIdentificationResponseBuilder |
| // WithLevel adds Level (property field) |
| WithLevel(ModbusDeviceInformationLevel) ModbusPDUReadDeviceIdentificationResponseBuilder |
| // WithIndividualAccess adds IndividualAccess (property field) |
| WithIndividualAccess(bool) ModbusPDUReadDeviceIdentificationResponseBuilder |
| // WithConformityLevel adds ConformityLevel (property field) |
| WithConformityLevel(ModbusDeviceInformationConformityLevel) ModbusPDUReadDeviceIdentificationResponseBuilder |
| // WithMoreFollows adds MoreFollows (property field) |
| WithMoreFollows(ModbusDeviceInformationMoreFollows) ModbusPDUReadDeviceIdentificationResponseBuilder |
| // WithNextObjectId adds NextObjectId (property field) |
| WithNextObjectId(uint8) ModbusPDUReadDeviceIdentificationResponseBuilder |
| // WithObjects adds Objects (property field) |
| WithObjects(...ModbusDeviceInformationObject) ModbusPDUReadDeviceIdentificationResponseBuilder |
| // Done is used to finish work on this child and return (or create one if none) to the parent builder |
| Done() ModbusPDUBuilder |
| // Build builds the ModbusPDUReadDeviceIdentificationResponse or returns an error if something is wrong |
| Build() (ModbusPDUReadDeviceIdentificationResponse, error) |
| // MustBuild does the same as Build but panics on error |
| MustBuild() ModbusPDUReadDeviceIdentificationResponse |
| } |
| |
| // NewModbusPDUReadDeviceIdentificationResponseBuilder() creates a ModbusPDUReadDeviceIdentificationResponseBuilder |
| func NewModbusPDUReadDeviceIdentificationResponseBuilder() ModbusPDUReadDeviceIdentificationResponseBuilder { |
| return &_ModbusPDUReadDeviceIdentificationResponseBuilder{_ModbusPDUReadDeviceIdentificationResponse: new(_ModbusPDUReadDeviceIdentificationResponse)} |
| } |
| |
| type _ModbusPDUReadDeviceIdentificationResponseBuilder struct { |
| *_ModbusPDUReadDeviceIdentificationResponse |
| |
| parentBuilder *_ModbusPDUBuilder |
| |
| collectedErr []error |
| } |
| |
| var _ (ModbusPDUReadDeviceIdentificationResponseBuilder) = (*_ModbusPDUReadDeviceIdentificationResponseBuilder)(nil) |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) setParent(contract ModbusPDUContract) { |
| b.ModbusPDUContract = contract |
| contract.(*_ModbusPDU)._SubType = b._ModbusPDUReadDeviceIdentificationResponse |
| } |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) WithMandatoryFields(level ModbusDeviceInformationLevel, individualAccess bool, conformityLevel ModbusDeviceInformationConformityLevel, moreFollows ModbusDeviceInformationMoreFollows, nextObjectId uint8, objects []ModbusDeviceInformationObject) ModbusPDUReadDeviceIdentificationResponseBuilder { |
| return b.WithLevel(level).WithIndividualAccess(individualAccess).WithConformityLevel(conformityLevel).WithMoreFollows(moreFollows).WithNextObjectId(nextObjectId).WithObjects(objects...) |
| } |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) WithLevel(level ModbusDeviceInformationLevel) ModbusPDUReadDeviceIdentificationResponseBuilder { |
| b.Level = level |
| return b |
| } |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) WithIndividualAccess(individualAccess bool) ModbusPDUReadDeviceIdentificationResponseBuilder { |
| b.IndividualAccess = individualAccess |
| return b |
| } |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) WithConformityLevel(conformityLevel ModbusDeviceInformationConformityLevel) ModbusPDUReadDeviceIdentificationResponseBuilder { |
| b.ConformityLevel = conformityLevel |
| return b |
| } |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) WithMoreFollows(moreFollows ModbusDeviceInformationMoreFollows) ModbusPDUReadDeviceIdentificationResponseBuilder { |
| b.MoreFollows = moreFollows |
| return b |
| } |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) WithNextObjectId(nextObjectId uint8) ModbusPDUReadDeviceIdentificationResponseBuilder { |
| b.NextObjectId = nextObjectId |
| return b |
| } |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) WithObjects(objects ...ModbusDeviceInformationObject) ModbusPDUReadDeviceIdentificationResponseBuilder { |
| b.Objects = objects |
| return b |
| } |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) Build() (ModbusPDUReadDeviceIdentificationResponse, error) { |
| if err := stdErrors.Join(b.collectedErr...); err != nil { |
| return nil, errors.Wrap(err, "error occurred during build") |
| } |
| return b._ModbusPDUReadDeviceIdentificationResponse.deepCopy(), nil |
| } |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) MustBuild() ModbusPDUReadDeviceIdentificationResponse { |
| build, err := b.Build() |
| if err != nil { |
| panic(err) |
| } |
| return build |
| } |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) Done() ModbusPDUBuilder { |
| if b.parentBuilder == nil { |
| b.parentBuilder = NewModbusPDUBuilder().(*_ModbusPDUBuilder) |
| } |
| return b.parentBuilder |
| } |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) buildForModbusPDU() (ModbusPDU, error) { |
| return b.Build() |
| } |
| |
| func (b *_ModbusPDUReadDeviceIdentificationResponseBuilder) DeepCopy() any { |
| _copy := b.CreateModbusPDUReadDeviceIdentificationResponseBuilder().(*_ModbusPDUReadDeviceIdentificationResponseBuilder) |
| if b.collectedErr != nil { |
| copy(_copy.collectedErr, b.collectedErr) |
| } |
| return _copy |
| } |
| |
| // CreateModbusPDUReadDeviceIdentificationResponseBuilder creates a ModbusPDUReadDeviceIdentificationResponseBuilder |
| func (b *_ModbusPDUReadDeviceIdentificationResponse) CreateModbusPDUReadDeviceIdentificationResponseBuilder() ModbusPDUReadDeviceIdentificationResponseBuilder { |
| if b == nil { |
| return NewModbusPDUReadDeviceIdentificationResponseBuilder() |
| } |
| return &_ModbusPDUReadDeviceIdentificationResponseBuilder{_ModbusPDUReadDeviceIdentificationResponse: b.deepCopy()} |
| } |
| |
| /////////////////////// |
| /////////////////////// |
| /////////////////////////////////////////////////////////// |
| /////////////////////////////////////////////////////////// |
| |
| /////////////////////////////////////////////////////////// |
| /////////////////////////////////////////////////////////// |
| /////////////////////// Accessors for discriminator values. |
| /////////////////////// |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetErrorFlag() bool { |
| return bool(false) |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetFunctionFlag() uint8 { |
| return 0x2B |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetResponse() bool { |
| return bool(true) |
| } |
| |
| /////////////////////// |
| /////////////////////// |
| /////////////////////////////////////////////////////////// |
| /////////////////////////////////////////////////////////// |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetParent() ModbusPDUContract { |
| return m.ModbusPDUContract |
| } |
| |
| /////////////////////////////////////////////////////////// |
| /////////////////////////////////////////////////////////// |
| /////////////////////// Accessors for property fields. |
| /////////////////////// |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetLevel() ModbusDeviceInformationLevel { |
| return m.Level |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetIndividualAccess() bool { |
| return m.IndividualAccess |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetConformityLevel() ModbusDeviceInformationConformityLevel { |
| return m.ConformityLevel |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetMoreFollows() ModbusDeviceInformationMoreFollows { |
| return m.MoreFollows |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetNextObjectId() uint8 { |
| return m.NextObjectId |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetObjects() []ModbusDeviceInformationObject { |
| return m.Objects |
| } |
| |
| /////////////////////// |
| /////////////////////// |
| /////////////////////////////////////////////////////////// |
| /////////////////////////////////////////////////////////// |
| /////////////////////////////////////////////////////////// |
| /////////////////////////////////////////////////////////// |
| /////////////////////// Accessors for const fields. |
| /////////////////////// |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetMeiType() uint8 { |
| return ModbusPDUReadDeviceIdentificationResponse_MEITYPE |
| } |
| |
| /////////////////////// |
| /////////////////////// |
| /////////////////////////////////////////////////////////// |
| /////////////////////////////////////////////////////////// |
| |
| // Deprecated: use the interface for direct cast |
| func CastModbusPDUReadDeviceIdentificationResponse(structType any) ModbusPDUReadDeviceIdentificationResponse { |
| if casted, ok := structType.(ModbusPDUReadDeviceIdentificationResponse); ok { |
| return casted |
| } |
| if casted, ok := structType.(*ModbusPDUReadDeviceIdentificationResponse); ok { |
| return *casted |
| } |
| return nil |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetTypeName() string { |
| return "ModbusPDUReadDeviceIdentificationResponse" |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetLengthInBits(ctx context.Context) uint16 { |
| lengthInBits := uint16(m.ModbusPDUContract.(*_ModbusPDU).getLengthInBits(ctx)) |
| |
| // Const Field (meiType) |
| lengthInBits += 8 |
| |
| // Simple field (level) |
| lengthInBits += 8 |
| |
| // Simple field (individualAccess) |
| lengthInBits += 1 |
| |
| // Simple field (conformityLevel) |
| lengthInBits += 7 |
| |
| // Simple field (moreFollows) |
| lengthInBits += 8 |
| |
| // Simple field (nextObjectId) |
| lengthInBits += 8 |
| |
| // Implicit Field (numberOfObjects) |
| lengthInBits += 8 |
| |
| // Array field |
| if len(m.Objects) > 0 { |
| for _curItem, element := range m.Objects { |
| arrayCtx := utils.CreateArrayContext(ctx, len(m.Objects), _curItem) |
| lengthInBits += element.GetLengthInBits(arrayCtx) |
| } |
| } |
| |
| return lengthInBits |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) GetLengthInBytes(ctx context.Context) uint16 { |
| return m.GetLengthInBits(ctx) / 8 |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) parse(ctx context.Context, readBuffer utils.ReadBuffer, parent *_ModbusPDU, response bool) (__modbusPDUReadDeviceIdentificationResponse ModbusPDUReadDeviceIdentificationResponse, err error) { |
| m.ModbusPDUContract = parent |
| parent._SubType = m |
| positionAware := readBuffer |
| _ = positionAware |
| if pullErr := readBuffer.PullContext("ModbusPDUReadDeviceIdentificationResponse"); pullErr != nil { |
| return nil, errors.Wrap(pullErr, "Error pulling for ModbusPDUReadDeviceIdentificationResponse") |
| } |
| currentPos := positionAware.GetPos() |
| _ = currentPos |
| |
| meiType, err := ReadConstField[uint8](ctx, "meiType", ReadUnsignedByte(readBuffer, uint8(8)), ModbusPDUReadDeviceIdentificationResponse_MEITYPE) |
| if err != nil { |
| return nil, errors.Wrap(err, fmt.Sprintf("Error parsing 'meiType' field")) |
| } |
| _ = meiType |
| |
| level, err := ReadEnumField[ModbusDeviceInformationLevel](ctx, "level", "ModbusDeviceInformationLevel", ReadEnum(ModbusDeviceInformationLevelByValue, ReadUnsignedByte(readBuffer, uint8(8)))) |
| if err != nil { |
| return nil, errors.Wrap(err, fmt.Sprintf("Error parsing 'level' field")) |
| } |
| m.Level = level |
| |
| individualAccess, err := ReadSimpleField(ctx, "individualAccess", ReadBoolean(readBuffer)) |
| if err != nil { |
| return nil, errors.Wrap(err, fmt.Sprintf("Error parsing 'individualAccess' field")) |
| } |
| m.IndividualAccess = individualAccess |
| |
| conformityLevel, err := ReadEnumField[ModbusDeviceInformationConformityLevel](ctx, "conformityLevel", "ModbusDeviceInformationConformityLevel", ReadEnum(ModbusDeviceInformationConformityLevelByValue, ReadUnsignedByte(readBuffer, uint8(7)))) |
| if err != nil { |
| return nil, errors.Wrap(err, fmt.Sprintf("Error parsing 'conformityLevel' field")) |
| } |
| m.ConformityLevel = conformityLevel |
| |
| moreFollows, err := ReadEnumField[ModbusDeviceInformationMoreFollows](ctx, "moreFollows", "ModbusDeviceInformationMoreFollows", ReadEnum(ModbusDeviceInformationMoreFollowsByValue, ReadUnsignedByte(readBuffer, uint8(8)))) |
| if err != nil { |
| return nil, errors.Wrap(err, fmt.Sprintf("Error parsing 'moreFollows' field")) |
| } |
| m.MoreFollows = moreFollows |
| |
| nextObjectId, err := ReadSimpleField(ctx, "nextObjectId", ReadUnsignedByte(readBuffer, uint8(8))) |
| if err != nil { |
| return nil, errors.Wrap(err, fmt.Sprintf("Error parsing 'nextObjectId' field")) |
| } |
| m.NextObjectId = nextObjectId |
| |
| numberOfObjects, err := ReadImplicitField[uint8](ctx, "numberOfObjects", ReadUnsignedByte(readBuffer, uint8(8))) |
| if err != nil { |
| return nil, errors.Wrap(err, fmt.Sprintf("Error parsing 'numberOfObjects' field")) |
| } |
| _ = numberOfObjects |
| |
| objects, err := ReadCountArrayField[ModbusDeviceInformationObject](ctx, "objects", ReadComplex[ModbusDeviceInformationObject](ModbusDeviceInformationObjectParseWithBuffer, readBuffer), uint64(numberOfObjects)) |
| if err != nil { |
| return nil, errors.Wrap(err, fmt.Sprintf("Error parsing 'objects' field")) |
| } |
| m.Objects = objects |
| |
| if closeErr := readBuffer.CloseContext("ModbusPDUReadDeviceIdentificationResponse"); closeErr != nil { |
| return nil, errors.Wrap(closeErr, "Error closing for ModbusPDUReadDeviceIdentificationResponse") |
| } |
| |
| return m, nil |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) Serialize() ([]byte, error) { |
| wb := utils.NewWriteBufferByteBased(utils.WithInitialSizeForByteBasedBuffer(int(m.GetLengthInBytes(context.Background())))) |
| if err := m.SerializeWithWriteBuffer(context.Background(), wb); err != nil { |
| return nil, err |
| } |
| return wb.GetBytes(), nil |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) SerializeWithWriteBuffer(ctx context.Context, writeBuffer utils.WriteBuffer) error { |
| positionAware := writeBuffer |
| _ = positionAware |
| log := zerolog.Ctx(ctx) |
| _ = log |
| ser := func() error { |
| if pushErr := writeBuffer.PushContext("ModbusPDUReadDeviceIdentificationResponse"); pushErr != nil { |
| return errors.Wrap(pushErr, "Error pushing for ModbusPDUReadDeviceIdentificationResponse") |
| } |
| |
| if err := WriteConstField(ctx, "meiType", ModbusPDUReadDeviceIdentificationResponse_MEITYPE, WriteUnsignedByte(writeBuffer, 8)); err != nil { |
| return errors.Wrap(err, "Error serializing 'meiType' field") |
| } |
| |
| if err := WriteSimpleEnumField[ModbusDeviceInformationLevel](ctx, "level", "ModbusDeviceInformationLevel", m.GetLevel(), WriteEnum[ModbusDeviceInformationLevel, uint8](ModbusDeviceInformationLevel.GetValue, ModbusDeviceInformationLevel.PLC4XEnumName, WriteUnsignedByte(writeBuffer, 8))); err != nil { |
| return errors.Wrap(err, "Error serializing 'level' field") |
| } |
| |
| if err := WriteSimpleField[bool](ctx, "individualAccess", m.GetIndividualAccess(), WriteBoolean(writeBuffer)); err != nil { |
| return errors.Wrap(err, "Error serializing 'individualAccess' field") |
| } |
| |
| if err := WriteSimpleEnumField[ModbusDeviceInformationConformityLevel](ctx, "conformityLevel", "ModbusDeviceInformationConformityLevel", m.GetConformityLevel(), WriteEnum[ModbusDeviceInformationConformityLevel, uint8](ModbusDeviceInformationConformityLevel.GetValue, ModbusDeviceInformationConformityLevel.PLC4XEnumName, WriteUnsignedByte(writeBuffer, 7))); err != nil { |
| return errors.Wrap(err, "Error serializing 'conformityLevel' field") |
| } |
| |
| if err := WriteSimpleEnumField[ModbusDeviceInformationMoreFollows](ctx, "moreFollows", "ModbusDeviceInformationMoreFollows", m.GetMoreFollows(), WriteEnum[ModbusDeviceInformationMoreFollows, uint8](ModbusDeviceInformationMoreFollows.GetValue, ModbusDeviceInformationMoreFollows.PLC4XEnumName, WriteUnsignedByte(writeBuffer, 8))); err != nil { |
| return errors.Wrap(err, "Error serializing 'moreFollows' field") |
| } |
| |
| if err := WriteSimpleField[uint8](ctx, "nextObjectId", m.GetNextObjectId(), WriteUnsignedByte(writeBuffer, 8)); err != nil { |
| return errors.Wrap(err, "Error serializing 'nextObjectId' field") |
| } |
| numberOfObjects := uint8(uint8(len(m.GetObjects()))) |
| if err := WriteImplicitField(ctx, "numberOfObjects", numberOfObjects, WriteUnsignedByte(writeBuffer, 8)); err != nil { |
| return errors.Wrap(err, "Error serializing 'numberOfObjects' field") |
| } |
| |
| if err := WriteComplexTypeArrayField(ctx, "objects", m.GetObjects(), writeBuffer); err != nil { |
| return errors.Wrap(err, "Error serializing 'objects' field") |
| } |
| |
| if popErr := writeBuffer.PopContext("ModbusPDUReadDeviceIdentificationResponse"); popErr != nil { |
| return errors.Wrap(popErr, "Error popping for ModbusPDUReadDeviceIdentificationResponse") |
| } |
| return nil |
| } |
| return m.ModbusPDUContract.(*_ModbusPDU).serializeParent(ctx, writeBuffer, m, ser) |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) IsModbusPDUReadDeviceIdentificationResponse() {} |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) DeepCopy() any { |
| return m.deepCopy() |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) deepCopy() *_ModbusPDUReadDeviceIdentificationResponse { |
| if m == nil { |
| return nil |
| } |
| _ModbusPDUReadDeviceIdentificationResponseCopy := &_ModbusPDUReadDeviceIdentificationResponse{ |
| m.ModbusPDUContract.(*_ModbusPDU).deepCopy(), |
| m.Level, |
| m.IndividualAccess, |
| m.ConformityLevel, |
| m.MoreFollows, |
| m.NextObjectId, |
| utils.DeepCopySlice[ModbusDeviceInformationObject, ModbusDeviceInformationObject](m.Objects), |
| } |
| _ModbusPDUReadDeviceIdentificationResponseCopy.ModbusPDUContract.(*_ModbusPDU)._SubType = m |
| return _ModbusPDUReadDeviceIdentificationResponseCopy |
| } |
| |
| func (m *_ModbusPDUReadDeviceIdentificationResponse) String() string { |
| if m == nil { |
| return "<nil>" |
| } |
| wb := utils.NewWriteBufferBoxBased( |
| utils.WithWriteBufferBoxBasedMergeSingleBoxes(), |
| utils.WithWriteBufferBoxBasedOmitEmptyBoxes(), |
| utils.WithWriteBufferBoxBasedPrintPosLengthFooter(), |
| ) |
| if err := wb.WriteSerializable(context.Background(), m); err != nil { |
| return err.Error() |
| } |
| return wb.GetBox().String() |
| } |