| Licensed to the Apache Software Foundation (ASF) under one |
| or more contributor license agreements. See the NOTICE file |
| distributed with this work for additional information |
| regarding copyright ownership. The ASF licenses this file |
| to you under the Apache License, Version 2.0 (the |
| "License"); you may not use this file except in compliance |
| with the License. You may obtain a copy of the License at |
| |
| http://www.apache.org/licenses/LICENSE-2.0 |
| |
| Unless required by applicable law or agreed to in writing, |
| software distributed under the License is distributed on an |
| "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY |
| KIND, either express or implied. See the License for the |
| specific language governing permissions and limitations |
| under the License. |
| */ |
| |
| #include <stdio.h> |
| #include <plc4c/spi/evaluation_helper.h> |
| #include "modbus_pdu.h" |
| |
| // Array of discriminator values that match the enum type constants. |
| // (The order is identical to the enum constants so we can use the |
| // enum constant to directly access a given types discriminator values) |
| const plc4c_modbus_read_write_modbus_pdu_discriminator plc4c_modbus_read_write_modbus_pdu_discriminators[] = { |
| {/* plc4c_modbus_read_write_modbus_pdu_error */ |
| .error = true, .function = -1, .response = -1}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_discrete_inputs_request */ |
| .error = false, .function = 0x02, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_discrete_inputs_response */ |
| .error = false, .function = 0x02, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_coils_request */ |
| .error = false, .function = 0x01, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_coils_response */ |
| .error = false, .function = 0x01, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_write_single_coil_request */ |
| .error = false, .function = 0x05, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_write_single_coil_response */ |
| .error = false, .function = 0x05, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_write_multiple_coils_request */ |
| .error = false, .function = 0x0F, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_write_multiple_coils_response */ |
| .error = false, .function = 0x0F, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_input_registers_request */ |
| .error = false, .function = 0x04, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_input_registers_response */ |
| .error = false, .function = 0x04, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_holding_registers_request */ |
| .error = false, .function = 0x03, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_holding_registers_response */ |
| .error = false, .function = 0x03, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_write_single_register_request */ |
| .error = false, .function = 0x06, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_write_single_register_response */ |
| .error = false, .function = 0x06, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_write_multiple_holding_registers_request */ |
| .error = false, .function = 0x10, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_write_multiple_holding_registers_response */ |
| .error = false, .function = 0x10, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_write_multiple_holding_registers_request */ |
| .error = false, .function = 0x17, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_write_multiple_holding_registers_response */ |
| .error = false, .function = 0x17, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_mask_write_holding_register_request */ |
| .error = false, .function = 0x16, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_mask_write_holding_register_response */ |
| .error = false, .function = 0x16, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_fifo_queue_request */ |
| .error = false, .function = 0x18, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_fifo_queue_response */ |
| .error = false, .function = 0x18, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_file_record_request */ |
| .error = false, .function = 0x14, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_file_record_response */ |
| .error = false, .function = 0x14, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_write_file_record_request */ |
| .error = false, .function = 0x15, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_write_file_record_response */ |
| .error = false, .function = 0x15, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_exception_status_request */ |
| .error = false, .function = 0x07, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_exception_status_response */ |
| .error = false, .function = 0x07, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_diagnostic_request */ |
| .error = false, .function = 0x08, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_get_com_event_log_request */ |
| .error = false, .function = 0x0C, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_get_com_event_log_response */ |
| .error = false, .function = 0x0C, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_report_server_id_request */ |
| .error = false, .function = 0x11, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_report_server_id_response */ |
| .error = false, .function = 0x11, .response = true}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_device_identification_request */ |
| .error = false, .function = 0x2B, .response = false}, |
| {/* plc4c_modbus_read_write_modbus_pdu_read_device_identification_response */ |
| .error = false, .function = 0x2B, .response = true} |
| }; |
| |
| // Function returning the discriminator values for a given type constant. |
| plc4c_modbus_read_write_modbus_pdu_discriminator plc4c_modbus_read_write_modbus_pdu_get_discriminator(plc4c_modbus_read_write_modbus_pdu_type type) { |
| return plc4c_modbus_read_write_modbus_pdu_discriminators[type]; |
| } |
| |
| // Create an empty NULL-struct |
| static const plc4c_modbus_read_write_modbus_pdu plc4c_modbus_read_write_modbus_pdu_null_const; |
| |
| plc4c_modbus_read_write_modbus_pdu plc4c_modbus_read_write_modbus_pdu_null() { |
| return plc4c_modbus_read_write_modbus_pdu_null_const; |
| } |
| |
| |
| // Parse function. |
| plc4c_return_code plc4c_modbus_read_write_modbus_pdu_parse(plc4c_spi_read_buffer* io, bool response, plc4c_modbus_read_write_modbus_pdu** _message) { |
| uint16_t startPos = plc4c_spi_read_get_pos(io); |
| uint16_t curPos; |
| plc4c_return_code _res = OK; |
| |
| // Allocate enough memory to contain this data structure. |
| (*_message) = malloc(sizeof(plc4c_modbus_read_write_modbus_pdu)); |
| if(*_message == NULL) { |
| return NO_MEMORY; |
| } |
| |
| // Discriminator Field (error) (Used as input to a switch field) |
| bool error = false; |
| _res = plc4c_spi_read_bit(io, (bool*) &error); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Discriminator Field (function) (Used as input to a switch field) |
| unsigned int function = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 7, (uint8_t*) &function); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Switch Field (Depending on the discriminator values, passes the instantiation to a sub-type) |
| if(error == true) { /* ModbusPDUError */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_error; |
| |
| // Simple Field (exceptionCode) |
| uint8_t exceptionCode = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &exceptionCode); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_error_exception_code = exceptionCode; |
| |
| } else |
| if((error == false) && (function == 0x02) && (response == false)) { /* ModbusPDUReadDiscreteInputsRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_discrete_inputs_request; |
| |
| // Simple Field (startingAddress) |
| uint16_t startingAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &startingAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_discrete_inputs_request_starting_address = startingAddress; |
| |
| |
| |
| // Simple Field (quantity) |
| uint16_t quantity = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_discrete_inputs_request_quantity = quantity; |
| |
| } else |
| if((error == false) && (function == 0x02) && (response == true)) { /* ModbusPDUReadDiscreteInputsResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_discrete_inputs_response; |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (value) |
| plc4c_list* value = NULL; |
| plc4c_utils_list_create(&value); |
| if(value == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Count array |
| uint8_t itemCount = byteCount; |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = malloc(sizeof(int8_t)); |
| _res = plc4c_spi_read_signed_byte(io, 8, (int8_t*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(value, _value); |
| } |
| } |
| (*_message)->modbus_pdu_read_discrete_inputs_response_value = value; |
| |
| } else |
| if((error == false) && (function == 0x01) && (response == false)) { /* ModbusPDUReadCoilsRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_coils_request; |
| |
| // Simple Field (startingAddress) |
| uint16_t startingAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &startingAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_coils_request_starting_address = startingAddress; |
| |
| |
| |
| // Simple Field (quantity) |
| uint16_t quantity = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_coils_request_quantity = quantity; |
| |
| } else |
| if((error == false) && (function == 0x01) && (response == true)) { /* ModbusPDUReadCoilsResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_coils_response; |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (value) |
| plc4c_list* value = NULL; |
| plc4c_utils_list_create(&value); |
| if(value == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Count array |
| uint8_t itemCount = byteCount; |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = malloc(sizeof(int8_t)); |
| _res = plc4c_spi_read_signed_byte(io, 8, (int8_t*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(value, _value); |
| } |
| } |
| (*_message)->modbus_pdu_read_coils_response_value = value; |
| |
| } else |
| if((error == false) && (function == 0x05) && (response == false)) { /* ModbusPDUWriteSingleCoilRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_single_coil_request; |
| |
| // Simple Field (address) |
| uint16_t address = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &address); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_single_coil_request_address = address; |
| |
| |
| |
| // Simple Field (value) |
| uint16_t value = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &value); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_single_coil_request_value = value; |
| |
| } else |
| if((error == false) && (function == 0x05) && (response == true)) { /* ModbusPDUWriteSingleCoilResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_single_coil_response; |
| |
| // Simple Field (address) |
| uint16_t address = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &address); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_single_coil_response_address = address; |
| |
| |
| |
| // Simple Field (value) |
| uint16_t value = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &value); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_single_coil_response_value = value; |
| |
| } else |
| if((error == false) && (function == 0x0F) && (response == false)) { /* ModbusPDUWriteMultipleCoilsRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_multiple_coils_request; |
| |
| // Simple Field (startingAddress) |
| uint16_t startingAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &startingAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_multiple_coils_request_starting_address = startingAddress; |
| |
| |
| |
| // Simple Field (quantity) |
| uint16_t quantity = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_multiple_coils_request_quantity = quantity; |
| |
| |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (value) |
| plc4c_list* value = NULL; |
| plc4c_utils_list_create(&value); |
| if(value == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Count array |
| uint8_t itemCount = byteCount; |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = malloc(sizeof(int8_t)); |
| _res = plc4c_spi_read_signed_byte(io, 8, (int8_t*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(value, _value); |
| } |
| } |
| (*_message)->modbus_pdu_write_multiple_coils_request_value = value; |
| |
| } else |
| if((error == false) && (function == 0x0F) && (response == true)) { /* ModbusPDUWriteMultipleCoilsResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_multiple_coils_response; |
| |
| // Simple Field (startingAddress) |
| uint16_t startingAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &startingAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_multiple_coils_response_starting_address = startingAddress; |
| |
| |
| |
| // Simple Field (quantity) |
| uint16_t quantity = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_multiple_coils_response_quantity = quantity; |
| |
| } else |
| if((error == false) && (function == 0x04) && (response == false)) { /* ModbusPDUReadInputRegistersRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_input_registers_request; |
| |
| // Simple Field (startingAddress) |
| uint16_t startingAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &startingAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_input_registers_request_starting_address = startingAddress; |
| |
| |
| |
| // Simple Field (quantity) |
| uint16_t quantity = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_input_registers_request_quantity = quantity; |
| |
| } else |
| if((error == false) && (function == 0x04) && (response == true)) { /* ModbusPDUReadInputRegistersResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_input_registers_response; |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (value) |
| plc4c_list* value = NULL; |
| plc4c_utils_list_create(&value); |
| if(value == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Count array |
| uint8_t itemCount = byteCount; |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = malloc(sizeof(int8_t)); |
| _res = plc4c_spi_read_signed_byte(io, 8, (int8_t*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(value, _value); |
| } |
| } |
| (*_message)->modbus_pdu_read_input_registers_response_value = value; |
| |
| } else |
| if((error == false) && (function == 0x03) && (response == false)) { /* ModbusPDUReadHoldingRegistersRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_holding_registers_request; |
| |
| // Simple Field (startingAddress) |
| uint16_t startingAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &startingAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_holding_registers_request_starting_address = startingAddress; |
| |
| |
| |
| // Simple Field (quantity) |
| uint16_t quantity = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_holding_registers_request_quantity = quantity; |
| |
| } else |
| if((error == false) && (function == 0x03) && (response == true)) { /* ModbusPDUReadHoldingRegistersResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_holding_registers_response; |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (value) |
| plc4c_list* value = NULL; |
| plc4c_utils_list_create(&value); |
| if(value == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Count array |
| uint8_t itemCount = byteCount; |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = malloc(sizeof(int8_t)); |
| _res = plc4c_spi_read_signed_byte(io, 8, (int8_t*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(value, _value); |
| } |
| } |
| (*_message)->modbus_pdu_read_holding_registers_response_value = value; |
| |
| } else |
| if((error == false) && (function == 0x06) && (response == false)) { /* ModbusPDUWriteSingleRegisterRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_single_register_request; |
| |
| // Simple Field (address) |
| uint16_t address = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &address); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_single_register_request_address = address; |
| |
| |
| |
| // Simple Field (value) |
| uint16_t value = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &value); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_single_register_request_value = value; |
| |
| } else |
| if((error == false) && (function == 0x06) && (response == true)) { /* ModbusPDUWriteSingleRegisterResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_single_register_response; |
| |
| // Simple Field (address) |
| uint16_t address = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &address); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_single_register_response_address = address; |
| |
| |
| |
| // Simple Field (value) |
| uint16_t value = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &value); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_single_register_response_value = value; |
| |
| } else |
| if((error == false) && (function == 0x10) && (response == false)) { /* ModbusPDUWriteMultipleHoldingRegistersRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_multiple_holding_registers_request; |
| |
| // Simple Field (startingAddress) |
| uint16_t startingAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &startingAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_multiple_holding_registers_request_starting_address = startingAddress; |
| |
| |
| |
| // Simple Field (quantity) |
| uint16_t quantity = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_multiple_holding_registers_request_quantity = quantity; |
| |
| |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (value) |
| plc4c_list* value = NULL; |
| plc4c_utils_list_create(&value); |
| if(value == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Count array |
| uint8_t itemCount = byteCount; |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = malloc(sizeof(int8_t)); |
| _res = plc4c_spi_read_signed_byte(io, 8, (int8_t*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(value, _value); |
| } |
| } |
| (*_message)->modbus_pdu_write_multiple_holding_registers_request_value = value; |
| |
| } else |
| if((error == false) && (function == 0x10) && (response == true)) { /* ModbusPDUWriteMultipleHoldingRegistersResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_multiple_holding_registers_response; |
| |
| // Simple Field (startingAddress) |
| uint16_t startingAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &startingAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_multiple_holding_registers_response_starting_address = startingAddress; |
| |
| |
| |
| // Simple Field (quantity) |
| uint16_t quantity = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_write_multiple_holding_registers_response_quantity = quantity; |
| |
| } else |
| if((error == false) && (function == 0x17) && (response == false)) { /* ModbusPDUReadWriteMultipleHoldingRegistersRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_write_multiple_holding_registers_request; |
| |
| // Simple Field (readStartingAddress) |
| uint16_t readStartingAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &readStartingAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_write_multiple_holding_registers_request_read_starting_address = readStartingAddress; |
| |
| |
| |
| // Simple Field (readQuantity) |
| uint16_t readQuantity = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &readQuantity); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_write_multiple_holding_registers_request_read_quantity = readQuantity; |
| |
| |
| |
| // Simple Field (writeStartingAddress) |
| uint16_t writeStartingAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &writeStartingAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_write_multiple_holding_registers_request_write_starting_address = writeStartingAddress; |
| |
| |
| |
| // Simple Field (writeQuantity) |
| uint16_t writeQuantity = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &writeQuantity); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_write_multiple_holding_registers_request_write_quantity = writeQuantity; |
| |
| |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (value) |
| plc4c_list* value = NULL; |
| plc4c_utils_list_create(&value); |
| if(value == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Count array |
| uint8_t itemCount = byteCount; |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = malloc(sizeof(int8_t)); |
| _res = plc4c_spi_read_signed_byte(io, 8, (int8_t*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(value, _value); |
| } |
| } |
| (*_message)->modbus_pdu_read_write_multiple_holding_registers_request_value = value; |
| |
| } else |
| if((error == false) && (function == 0x17) && (response == true)) { /* ModbusPDUReadWriteMultipleHoldingRegistersResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_write_multiple_holding_registers_response; |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (value) |
| plc4c_list* value = NULL; |
| plc4c_utils_list_create(&value); |
| if(value == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Count array |
| uint8_t itemCount = byteCount; |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = malloc(sizeof(int8_t)); |
| _res = plc4c_spi_read_signed_byte(io, 8, (int8_t*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(value, _value); |
| } |
| } |
| (*_message)->modbus_pdu_read_write_multiple_holding_registers_response_value = value; |
| |
| } else |
| if((error == false) && (function == 0x16) && (response == false)) { /* ModbusPDUMaskWriteHoldingRegisterRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_mask_write_holding_register_request; |
| |
| // Simple Field (referenceAddress) |
| uint16_t referenceAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &referenceAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_mask_write_holding_register_request_reference_address = referenceAddress; |
| |
| |
| |
| // Simple Field (andMask) |
| uint16_t andMask = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &andMask); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_mask_write_holding_register_request_and_mask = andMask; |
| |
| |
| |
| // Simple Field (orMask) |
| uint16_t orMask = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &orMask); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_mask_write_holding_register_request_or_mask = orMask; |
| |
| } else |
| if((error == false) && (function == 0x16) && (response == true)) { /* ModbusPDUMaskWriteHoldingRegisterResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_mask_write_holding_register_response; |
| |
| // Simple Field (referenceAddress) |
| uint16_t referenceAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &referenceAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_mask_write_holding_register_response_reference_address = referenceAddress; |
| |
| |
| |
| // Simple Field (andMask) |
| uint16_t andMask = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &andMask); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_mask_write_holding_register_response_and_mask = andMask; |
| |
| |
| |
| // Simple Field (orMask) |
| uint16_t orMask = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &orMask); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_mask_write_holding_register_response_or_mask = orMask; |
| |
| } else |
| if((error == false) && (function == 0x18) && (response == false)) { /* ModbusPDUReadFifoQueueRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_fifo_queue_request; |
| |
| // Simple Field (fifoPointerAddress) |
| uint16_t fifoPointerAddress = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &fifoPointerAddress); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_fifo_queue_request_fifo_pointer_address = fifoPointerAddress; |
| |
| } else |
| if((error == false) && (function == 0x18) && (response == true)) { /* ModbusPDUReadFifoQueueResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_fifo_queue_response; |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint16_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Implicit Field (fifoCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint16_t fifoCount = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &fifoCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (fifoValue) |
| plc4c_list* fifoValue = NULL; |
| plc4c_utils_list_create(&fifoValue); |
| if(fifoValue == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Count array |
| uint8_t itemCount = fifoCount; |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| uint16_t* _value = malloc(sizeof(uint16_t)); |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(fifoValue, _value); |
| } |
| } |
| (*_message)->modbus_pdu_read_fifo_queue_response_fifo_value = fifoValue; |
| |
| } else |
| if((error == false) && (function == 0x14) && (response == false)) { /* ModbusPDUReadFileRecordRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_file_record_request; |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (items) |
| plc4c_list* items = NULL; |
| plc4c_utils_list_create(&items); |
| if(items == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Length array |
| uint8_t _itemsLength = byteCount; |
| uint8_t itemsEndPos = plc4c_spi_read_get_pos(io) + _itemsLength; |
| while(plc4c_spi_read_get_pos(io) < itemsEndPos) { |
| plc4c_modbus_read_write_modbus_pdu_read_file_record_request_item* _value = NULL; |
| _res = plc4c_modbus_read_write_modbus_pdu_read_file_record_request_item_parse(io, (void*) &_value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(items, _value); |
| } |
| } |
| (*_message)->modbus_pdu_read_file_record_request_items = items; |
| |
| } else |
| if((error == false) && (function == 0x14) && (response == true)) { /* ModbusPDUReadFileRecordResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_file_record_response; |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (items) |
| plc4c_list* items = NULL; |
| plc4c_utils_list_create(&items); |
| if(items == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Length array |
| uint8_t _itemsLength = byteCount; |
| uint8_t itemsEndPos = plc4c_spi_read_get_pos(io) + _itemsLength; |
| while(plc4c_spi_read_get_pos(io) < itemsEndPos) { |
| plc4c_modbus_read_write_modbus_pdu_read_file_record_response_item* _value = NULL; |
| _res = plc4c_modbus_read_write_modbus_pdu_read_file_record_response_item_parse(io, (void*) &_value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(items, _value); |
| } |
| } |
| (*_message)->modbus_pdu_read_file_record_response_items = items; |
| |
| } else |
| if((error == false) && (function == 0x15) && (response == false)) { /* ModbusPDUWriteFileRecordRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_file_record_request; |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (items) |
| plc4c_list* items = NULL; |
| plc4c_utils_list_create(&items); |
| if(items == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Length array |
| uint8_t _itemsLength = byteCount; |
| uint8_t itemsEndPos = plc4c_spi_read_get_pos(io) + _itemsLength; |
| while(plc4c_spi_read_get_pos(io) < itemsEndPos) { |
| plc4c_modbus_read_write_modbus_pdu_write_file_record_request_item* _value = NULL; |
| _res = plc4c_modbus_read_write_modbus_pdu_write_file_record_request_item_parse(io, (void*) &_value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(items, _value); |
| } |
| } |
| (*_message)->modbus_pdu_write_file_record_request_items = items; |
| |
| } else |
| if((error == false) && (function == 0x15) && (response == true)) { /* ModbusPDUWriteFileRecordResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_file_record_response; |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (items) |
| plc4c_list* items = NULL; |
| plc4c_utils_list_create(&items); |
| if(items == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Length array |
| uint8_t _itemsLength = byteCount; |
| uint8_t itemsEndPos = plc4c_spi_read_get_pos(io) + _itemsLength; |
| while(plc4c_spi_read_get_pos(io) < itemsEndPos) { |
| plc4c_modbus_read_write_modbus_pdu_write_file_record_response_item* _value = NULL; |
| _res = plc4c_modbus_read_write_modbus_pdu_write_file_record_response_item_parse(io, (void*) &_value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(items, _value); |
| } |
| } |
| (*_message)->modbus_pdu_write_file_record_response_items = items; |
| |
| } else |
| if((error == false) && (function == 0x07) && (response == false)) { /* ModbusPDUReadExceptionStatusRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_exception_status_request; |
| } else |
| if((error == false) && (function == 0x07) && (response == true)) { /* ModbusPDUReadExceptionStatusResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_exception_status_response; |
| |
| // Simple Field (value) |
| uint8_t value = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &value); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_read_exception_status_response_value = value; |
| |
| } else |
| if((error == false) && (function == 0x08) && (response == false)) { /* ModbusPDUDiagnosticRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_diagnostic_request; |
| |
| // Simple Field (status) |
| uint16_t status = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &status); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_diagnostic_request_status = status; |
| |
| |
| |
| // Simple Field (eventCount) |
| uint16_t eventCount = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &eventCount); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_diagnostic_request_event_count = eventCount; |
| |
| } else |
| if((error == false) && (function == 0x0C) && (response == false)) { /* ModbusPDUGetComEventLogRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_get_com_event_log_request; |
| } else |
| if((error == false) && (function == 0x0C) && (response == true)) { /* ModbusPDUGetComEventLogResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_get_com_event_log_response; |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Simple Field (status) |
| uint16_t status = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &status); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_get_com_event_log_response_status = status; |
| |
| |
| |
| // Simple Field (eventCount) |
| uint16_t eventCount = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &eventCount); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_get_com_event_log_response_event_count = eventCount; |
| |
| |
| |
| // Simple Field (messageCount) |
| uint16_t messageCount = 0; |
| _res = plc4c_spi_read_unsigned_short(io, 16, (uint16_t*) &messageCount); |
| if(_res != OK) { |
| return _res; |
| } |
| (*_message)->modbus_pdu_get_com_event_log_response_message_count = messageCount; |
| |
| |
| |
| // Array field (events) |
| plc4c_list* events = NULL; |
| plc4c_utils_list_create(&events); |
| if(events == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Count array |
| uint8_t itemCount = (byteCount) - (6); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = malloc(sizeof(int8_t)); |
| _res = plc4c_spi_read_signed_byte(io, 8, (int8_t*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(events, _value); |
| } |
| } |
| (*_message)->modbus_pdu_get_com_event_log_response_events = events; |
| |
| } else |
| if((error == false) && (function == 0x11) && (response == false)) { /* ModbusPDUReportServerIdRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_report_server_id_request; |
| } else |
| if((error == false) && (function == 0x11) && (response == true)) { /* ModbusPDUReportServerIdResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_report_server_id_response; |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| uint8_t byteCount = 0; |
| _res = plc4c_spi_read_unsigned_byte(io, 8, (uint8_t*) &byteCount); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| |
| |
| // Array field (value) |
| plc4c_list* value = NULL; |
| plc4c_utils_list_create(&value); |
| if(value == NULL) { |
| return NO_MEMORY; |
| } |
| { |
| // Count array |
| uint8_t itemCount = byteCount; |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = malloc(sizeof(int8_t)); |
| _res = plc4c_spi_read_signed_byte(io, 8, (int8_t*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| plc4c_utils_list_insert_head_value(value, _value); |
| } |
| } |
| (*_message)->modbus_pdu_report_server_id_response_value = value; |
| |
| } else |
| if((error == false) && (function == 0x2B) && (response == false)) { /* ModbusPDUReadDeviceIdentificationRequest */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_device_identification_request; |
| } else |
| if((error == false) && (function == 0x2B) && (response == true)) { /* ModbusPDUReadDeviceIdentificationResponse */ |
| (*_message)->_type = plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_device_identification_response; |
| } |
| |
| return OK; |
| } |
| |
| plc4c_return_code plc4c_modbus_read_write_modbus_pdu_serialize(plc4c_spi_write_buffer* io, plc4c_modbus_read_write_modbus_pdu* _message) { |
| plc4c_return_code _res = OK; |
| |
| // Discriminator Field (error) |
| plc4c_spi_write_bit(io, plc4c_modbus_read_write_modbus_pdu_get_discriminator(_message->_type).error); |
| |
| // Discriminator Field (function) |
| plc4c_spi_write_unsigned_byte(io, 7, plc4c_modbus_read_write_modbus_pdu_get_discriminator(_message->_type).function); |
| |
| // Switch Field (Depending of the current type, serialize the sub-type elements) |
| switch(_message->_type) { |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_error: { |
| |
| // Simple Field (exceptionCode) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, _message->modbus_pdu_error_exception_code); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_discrete_inputs_request: { |
| |
| // Simple Field (startingAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_discrete_inputs_request_starting_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (quantity) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_discrete_inputs_request_quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_discrete_inputs_response: { |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_count(_message->modbus_pdu_read_discrete_inputs_response_value)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (value) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_read_discrete_inputs_response_value); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = (int8_t*) plc4c_utils_list_get_value(_message->modbus_pdu_read_discrete_inputs_response_value, curItem); |
| plc4c_spi_write_signed_byte(io, 8, *_value); |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_coils_request: { |
| |
| // Simple Field (startingAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_coils_request_starting_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (quantity) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_coils_request_quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_coils_response: { |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_count(_message->modbus_pdu_read_coils_response_value)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (value) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_read_coils_response_value); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = (int8_t*) plc4c_utils_list_get_value(_message->modbus_pdu_read_coils_response_value, curItem); |
| plc4c_spi_write_signed_byte(io, 8, *_value); |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_single_coil_request: { |
| |
| // Simple Field (address) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_single_coil_request_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (value) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_single_coil_request_value); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_single_coil_response: { |
| |
| // Simple Field (address) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_single_coil_response_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (value) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_single_coil_response_value); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_multiple_coils_request: { |
| |
| // Simple Field (startingAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_multiple_coils_request_starting_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (quantity) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_multiple_coils_request_quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_count(_message->modbus_pdu_write_multiple_coils_request_value)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (value) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_write_multiple_coils_request_value); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = (int8_t*) plc4c_utils_list_get_value(_message->modbus_pdu_write_multiple_coils_request_value, curItem); |
| plc4c_spi_write_signed_byte(io, 8, *_value); |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_multiple_coils_response: { |
| |
| // Simple Field (startingAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_multiple_coils_response_starting_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (quantity) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_multiple_coils_response_quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_input_registers_request: { |
| |
| // Simple Field (startingAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_input_registers_request_starting_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (quantity) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_input_registers_request_quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_input_registers_response: { |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_count(_message->modbus_pdu_read_input_registers_response_value)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (value) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_read_input_registers_response_value); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = (int8_t*) plc4c_utils_list_get_value(_message->modbus_pdu_read_input_registers_response_value, curItem); |
| plc4c_spi_write_signed_byte(io, 8, *_value); |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_holding_registers_request: { |
| |
| // Simple Field (startingAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_holding_registers_request_starting_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (quantity) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_holding_registers_request_quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_holding_registers_response: { |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_count(_message->modbus_pdu_read_holding_registers_response_value)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (value) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_read_holding_registers_response_value); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = (int8_t*) plc4c_utils_list_get_value(_message->modbus_pdu_read_holding_registers_response_value, curItem); |
| plc4c_spi_write_signed_byte(io, 8, *_value); |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_single_register_request: { |
| |
| // Simple Field (address) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_single_register_request_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (value) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_single_register_request_value); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_single_register_response: { |
| |
| // Simple Field (address) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_single_register_response_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (value) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_single_register_response_value); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_multiple_holding_registers_request: { |
| |
| // Simple Field (startingAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_multiple_holding_registers_request_starting_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (quantity) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_multiple_holding_registers_request_quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_count(_message->modbus_pdu_write_multiple_holding_registers_request_value)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (value) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_write_multiple_holding_registers_request_value); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = (int8_t*) plc4c_utils_list_get_value(_message->modbus_pdu_write_multiple_holding_registers_request_value, curItem); |
| plc4c_spi_write_signed_byte(io, 8, *_value); |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_multiple_holding_registers_response: { |
| |
| // Simple Field (startingAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_multiple_holding_registers_response_starting_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (quantity) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_write_multiple_holding_registers_response_quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_write_multiple_holding_registers_request: { |
| |
| // Simple Field (readStartingAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_write_multiple_holding_registers_request_read_starting_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (readQuantity) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_write_multiple_holding_registers_request_read_quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (writeStartingAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_write_multiple_holding_registers_request_write_starting_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (writeQuantity) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_write_multiple_holding_registers_request_write_quantity); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_count(_message->modbus_pdu_read_write_multiple_holding_registers_request_value)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (value) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_read_write_multiple_holding_registers_request_value); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = (int8_t*) plc4c_utils_list_get_value(_message->modbus_pdu_read_write_multiple_holding_registers_request_value, curItem); |
| plc4c_spi_write_signed_byte(io, 8, *_value); |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_write_multiple_holding_registers_response: { |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_count(_message->modbus_pdu_read_write_multiple_holding_registers_response_value)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (value) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_read_write_multiple_holding_registers_response_value); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = (int8_t*) plc4c_utils_list_get_value(_message->modbus_pdu_read_write_multiple_holding_registers_response_value, curItem); |
| plc4c_spi_write_signed_byte(io, 8, *_value); |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_mask_write_holding_register_request: { |
| |
| // Simple Field (referenceAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_mask_write_holding_register_request_reference_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (andMask) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_mask_write_holding_register_request_and_mask); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (orMask) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_mask_write_holding_register_request_or_mask); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_mask_write_holding_register_response: { |
| |
| // Simple Field (referenceAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_mask_write_holding_register_response_reference_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (andMask) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_mask_write_holding_register_response_and_mask); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (orMask) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_mask_write_holding_register_response_or_mask); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_fifo_queue_request: { |
| |
| // Simple Field (fifoPointerAddress) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_read_fifo_queue_request_fifo_pointer_address); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_fifo_queue_response: { |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_short(io, 16, (((plc4c_spi_evaluation_helper_count(_message->modbus_pdu_read_fifo_queue_response_fifo_value)) * (2))) + (2)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Implicit Field (fifoCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_short(io, 16, (((plc4c_spi_evaluation_helper_count(_message->modbus_pdu_read_fifo_queue_response_fifo_value)) * (2))) / (2)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (fifoValue) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_read_fifo_queue_response_fifo_value); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| uint16_t* _value = (uint16_t*) plc4c_utils_list_get_value(_message->modbus_pdu_read_fifo_queue_response_fifo_value, curItem); |
| plc4c_spi_write_unsigned_short(io, 16, *_value); |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_file_record_request: { |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_array_size_in_bytes(_message->modbus_pdu_read_file_record_request_items)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (items) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_read_file_record_request_items); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| bool lastItem = curItem == (itemCount - 1); |
| plc4c_modbus_read_write_modbus_pdu_read_file_record_request_item* _value = (plc4c_modbus_read_write_modbus_pdu_read_file_record_request_item*) plc4c_utils_list_get_value(_message->modbus_pdu_read_file_record_request_items, curItem); |
| _res = plc4c_modbus_read_write_modbus_pdu_read_file_record_request_item_serialize(io, (void*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_file_record_response: { |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_array_size_in_bytes(_message->modbus_pdu_read_file_record_response_items)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (items) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_read_file_record_response_items); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| bool lastItem = curItem == (itemCount - 1); |
| plc4c_modbus_read_write_modbus_pdu_read_file_record_response_item* _value = (plc4c_modbus_read_write_modbus_pdu_read_file_record_response_item*) plc4c_utils_list_get_value(_message->modbus_pdu_read_file_record_response_items, curItem); |
| _res = plc4c_modbus_read_write_modbus_pdu_read_file_record_response_item_serialize(io, (void*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_file_record_request: { |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_array_size_in_bytes(_message->modbus_pdu_write_file_record_request_items)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (items) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_write_file_record_request_items); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| bool lastItem = curItem == (itemCount - 1); |
| plc4c_modbus_read_write_modbus_pdu_write_file_record_request_item* _value = (plc4c_modbus_read_write_modbus_pdu_write_file_record_request_item*) plc4c_utils_list_get_value(_message->modbus_pdu_write_file_record_request_items, curItem); |
| _res = plc4c_modbus_read_write_modbus_pdu_write_file_record_request_item_serialize(io, (void*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_file_record_response: { |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_array_size_in_bytes(_message->modbus_pdu_write_file_record_response_items)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (items) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_write_file_record_response_items); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| bool lastItem = curItem == (itemCount - 1); |
| plc4c_modbus_read_write_modbus_pdu_write_file_record_response_item* _value = (plc4c_modbus_read_write_modbus_pdu_write_file_record_response_item*) plc4c_utils_list_get_value(_message->modbus_pdu_write_file_record_response_items, curItem); |
| _res = plc4c_modbus_read_write_modbus_pdu_write_file_record_response_item_serialize(io, (void*) _value); |
| if(_res != OK) { |
| return _res; |
| } |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_exception_status_request: { |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_exception_status_response: { |
| |
| // Simple Field (value) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, _message->modbus_pdu_read_exception_status_response_value); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_diagnostic_request: { |
| |
| // Simple Field (status) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_diagnostic_request_status); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (eventCount) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_diagnostic_request_event_count); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_get_com_event_log_request: { |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_get_com_event_log_response: { |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, (plc4c_spi_evaluation_helper_count(_message->modbus_pdu_get_com_event_log_response_events)) + (6)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (status) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_get_com_event_log_response_status); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (eventCount) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_get_com_event_log_response_event_count); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Simple Field (messageCount) |
| _res = plc4c_spi_write_unsigned_short(io, 16, _message->modbus_pdu_get_com_event_log_response_message_count); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (events) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_get_com_event_log_response_events); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = (int8_t*) plc4c_utils_list_get_value(_message->modbus_pdu_get_com_event_log_response_events, curItem); |
| plc4c_spi_write_signed_byte(io, 8, *_value); |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_report_server_id_request: { |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_report_server_id_response: { |
| |
| // Implicit Field (byteCount) (Used for parsing, but it's value is not stored as it's implicitly given by the objects content) |
| _res = plc4c_spi_write_unsigned_byte(io, 8, plc4c_spi_evaluation_helper_count(_message->modbus_pdu_report_server_id_response_value)); |
| if(_res != OK) { |
| return _res; |
| } |
| |
| // Array field (value) |
| { |
| uint8_t itemCount = plc4c_utils_list_size(_message->modbus_pdu_report_server_id_response_value); |
| for(int curItem = 0; curItem < itemCount; curItem++) { |
| |
| int8_t* _value = (int8_t*) plc4c_utils_list_get_value(_message->modbus_pdu_report_server_id_response_value, curItem); |
| plc4c_spi_write_signed_byte(io, 8, *_value); |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_device_identification_request: { |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_device_identification_response: { |
| |
| break; |
| } |
| } |
| |
| return OK; |
| } |
| |
| uint16_t plc4c_modbus_read_write_modbus_pdu_length_in_bytes(plc4c_modbus_read_write_modbus_pdu* _message) { |
| return plc4c_modbus_read_write_modbus_pdu_length_in_bits(_message) / 8; |
| } |
| |
| uint16_t plc4c_modbus_read_write_modbus_pdu_length_in_bits(plc4c_modbus_read_write_modbus_pdu* _message) { |
| uint16_t lengthInBits = 0; |
| |
| // Discriminator Field (error) |
| lengthInBits += 1; |
| |
| // Discriminator Field (function) |
| lengthInBits += 7; |
| |
| // Depending of the current type, add the length of sub-type elements ... |
| switch(_message->_type) { |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_error: { |
| |
| // Simple field (exceptionCode) |
| lengthInBits += 8; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_discrete_inputs_request: { |
| |
| // Simple field (startingAddress) |
| lengthInBits += 16; |
| |
| |
| // Simple field (quantity) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_discrete_inputs_response: { |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| lengthInBits += 8 * plc4c_utils_list_size(_message->modbus_pdu_read_discrete_inputs_response_value); |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_coils_request: { |
| |
| // Simple field (startingAddress) |
| lengthInBits += 16; |
| |
| |
| // Simple field (quantity) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_coils_response: { |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| lengthInBits += 8 * plc4c_utils_list_size(_message->modbus_pdu_read_coils_response_value); |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_single_coil_request: { |
| |
| // Simple field (address) |
| lengthInBits += 16; |
| |
| |
| // Simple field (value) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_single_coil_response: { |
| |
| // Simple field (address) |
| lengthInBits += 16; |
| |
| |
| // Simple field (value) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_multiple_coils_request: { |
| |
| // Simple field (startingAddress) |
| lengthInBits += 16; |
| |
| |
| // Simple field (quantity) |
| lengthInBits += 16; |
| |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| lengthInBits += 8 * plc4c_utils_list_size(_message->modbus_pdu_write_multiple_coils_request_value); |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_multiple_coils_response: { |
| |
| // Simple field (startingAddress) |
| lengthInBits += 16; |
| |
| |
| // Simple field (quantity) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_input_registers_request: { |
| |
| // Simple field (startingAddress) |
| lengthInBits += 16; |
| |
| |
| // Simple field (quantity) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_input_registers_response: { |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| lengthInBits += 8 * plc4c_utils_list_size(_message->modbus_pdu_read_input_registers_response_value); |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_holding_registers_request: { |
| |
| // Simple field (startingAddress) |
| lengthInBits += 16; |
| |
| |
| // Simple field (quantity) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_holding_registers_response: { |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| lengthInBits += 8 * plc4c_utils_list_size(_message->modbus_pdu_read_holding_registers_response_value); |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_single_register_request: { |
| |
| // Simple field (address) |
| lengthInBits += 16; |
| |
| |
| // Simple field (value) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_single_register_response: { |
| |
| // Simple field (address) |
| lengthInBits += 16; |
| |
| |
| // Simple field (value) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_multiple_holding_registers_request: { |
| |
| // Simple field (startingAddress) |
| lengthInBits += 16; |
| |
| |
| // Simple field (quantity) |
| lengthInBits += 16; |
| |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| lengthInBits += 8 * plc4c_utils_list_size(_message->modbus_pdu_write_multiple_holding_registers_request_value); |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_multiple_holding_registers_response: { |
| |
| // Simple field (startingAddress) |
| lengthInBits += 16; |
| |
| |
| // Simple field (quantity) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_write_multiple_holding_registers_request: { |
| |
| // Simple field (readStartingAddress) |
| lengthInBits += 16; |
| |
| |
| // Simple field (readQuantity) |
| lengthInBits += 16; |
| |
| |
| // Simple field (writeStartingAddress) |
| lengthInBits += 16; |
| |
| |
| // Simple field (writeQuantity) |
| lengthInBits += 16; |
| |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| lengthInBits += 8 * plc4c_utils_list_size(_message->modbus_pdu_read_write_multiple_holding_registers_request_value); |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_write_multiple_holding_registers_response: { |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| lengthInBits += 8 * plc4c_utils_list_size(_message->modbus_pdu_read_write_multiple_holding_registers_response_value); |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_mask_write_holding_register_request: { |
| |
| // Simple field (referenceAddress) |
| lengthInBits += 16; |
| |
| |
| // Simple field (andMask) |
| lengthInBits += 16; |
| |
| |
| // Simple field (orMask) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_mask_write_holding_register_response: { |
| |
| // Simple field (referenceAddress) |
| lengthInBits += 16; |
| |
| |
| // Simple field (andMask) |
| lengthInBits += 16; |
| |
| |
| // Simple field (orMask) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_fifo_queue_request: { |
| |
| // Simple field (fifoPointerAddress) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_fifo_queue_response: { |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 16; |
| |
| |
| // Implicit Field (fifoCount) |
| lengthInBits += 16; |
| |
| |
| // Array field |
| lengthInBits += 16 * plc4c_utils_list_size(_message->modbus_pdu_read_fifo_queue_response_fifo_value); |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_file_record_request: { |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| if(_message->modbus_pdu_read_file_record_request_items != NULL) { |
| plc4c_list_element* curElement = _message->modbus_pdu_read_file_record_request_items->tail; |
| while (curElement != NULL) { |
| lengthInBits += plc4c_modbus_read_write_modbus_pdu_read_file_record_request_item_length_in_bits((plc4c_modbus_read_write_modbus_pdu_read_file_record_request_item*) curElement->value); |
| curElement = curElement->next; |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_file_record_response: { |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| if(_message->modbus_pdu_read_file_record_response_items != NULL) { |
| plc4c_list_element* curElement = _message->modbus_pdu_read_file_record_response_items->tail; |
| while (curElement != NULL) { |
| lengthInBits += plc4c_modbus_read_write_modbus_pdu_read_file_record_response_item_length_in_bits((plc4c_modbus_read_write_modbus_pdu_read_file_record_response_item*) curElement->value); |
| curElement = curElement->next; |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_file_record_request: { |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| if(_message->modbus_pdu_write_file_record_request_items != NULL) { |
| plc4c_list_element* curElement = _message->modbus_pdu_write_file_record_request_items->tail; |
| while (curElement != NULL) { |
| lengthInBits += plc4c_modbus_read_write_modbus_pdu_write_file_record_request_item_length_in_bits((plc4c_modbus_read_write_modbus_pdu_write_file_record_request_item*) curElement->value); |
| curElement = curElement->next; |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_write_file_record_response: { |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| if(_message->modbus_pdu_write_file_record_response_items != NULL) { |
| plc4c_list_element* curElement = _message->modbus_pdu_write_file_record_response_items->tail; |
| while (curElement != NULL) { |
| lengthInBits += plc4c_modbus_read_write_modbus_pdu_write_file_record_response_item_length_in_bits((plc4c_modbus_read_write_modbus_pdu_write_file_record_response_item*) curElement->value); |
| curElement = curElement->next; |
| } |
| } |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_exception_status_request: { |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_exception_status_response: { |
| |
| // Simple field (value) |
| lengthInBits += 8; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_diagnostic_request: { |
| |
| // Simple field (status) |
| lengthInBits += 16; |
| |
| |
| // Simple field (eventCount) |
| lengthInBits += 16; |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_get_com_event_log_request: { |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_get_com_event_log_response: { |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Simple field (status) |
| lengthInBits += 16; |
| |
| |
| // Simple field (eventCount) |
| lengthInBits += 16; |
| |
| |
| // Simple field (messageCount) |
| lengthInBits += 16; |
| |
| |
| // Array field |
| lengthInBits += 8 * plc4c_utils_list_size(_message->modbus_pdu_get_com_event_log_response_events); |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_report_server_id_request: { |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_report_server_id_response: { |
| |
| // Implicit Field (byteCount) |
| lengthInBits += 8; |
| |
| |
| // Array field |
| lengthInBits += 8 * plc4c_utils_list_size(_message->modbus_pdu_report_server_id_response_value); |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_device_identification_request: { |
| |
| break; |
| } |
| case plc4c_modbus_read_write_modbus_pdu_type_plc4c_modbus_read_write_modbus_pdu_read_device_identification_response: { |
| |
| break; |
| } |
| } |
| |
| return lengthInBits; |
| } |
| |