blob: 19304ba7346ce12a376f27758961088acff11c95 [file] [log] [blame]
//
// Licensed to the Apache Software Foundation (ASF) under one
// or more contributor license agreements. See the NOTICE file
// distributed with this work for additional information
// regarding copyright ownership. The ASF licenses this file
// to you under the Apache License, Version 2.0 (the
// "License"); you may not use this file except in compliance
// with the License. You may obtain a copy of the License at
//
// http://www.apache.org/licenses/LICENSE-2.0
//
// Unless required by applicable law or agreed to in writing,
// software distributed under the License is distributed on an
// "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY
// KIND, either express or implied. See the License for the
// specific language governing permissions and limitations
// under the License.
//
package model
import (
"github.com/apache/plc4x/plc4go/internal/plc4go/spi/utils"
"github.com/pkg/errors"
)
// Code generated by build-utils. DO NOT EDIT.
// The data-structure of this message
type ModbusPDU struct {
Child IModbusPDUChild
}
// The corresponding interface
type IModbusPDU interface {
ErrorFlag() bool
FunctionFlag() uint8
Response() bool
LengthInBytes() uint16
LengthInBits() uint16
Serialize(writeBuffer utils.WriteBuffer) error
}
type IModbusPDUParent interface {
SerializeParent(writeBuffer utils.WriteBuffer, child IModbusPDU, serializeChildFunction func() error) error
GetTypeName() string
}
type IModbusPDUChild interface {
Serialize(writeBuffer utils.WriteBuffer) error
InitializeParent(parent *ModbusPDU)
GetTypeName() string
IModbusPDU
}
func NewModbusPDU() *ModbusPDU {
return &ModbusPDU{}
}
func CastModbusPDU(structType interface{}) *ModbusPDU {
castFunc := func(typ interface{}) *ModbusPDU {
if casted, ok := typ.(ModbusPDU); ok {
return &casted
}
if casted, ok := typ.(*ModbusPDU); ok {
return casted
}
return nil
}
return castFunc(structType)
}
func (m *ModbusPDU) GetTypeName() string {
return "ModbusPDU"
}
func (m *ModbusPDU) LengthInBits() uint16 {
return m.LengthInBitsConditional(false)
}
func (m *ModbusPDU) LengthInBitsConditional(lastItem bool) uint16 {
return m.Child.LengthInBits()
}
func (m *ModbusPDU) ParentLengthInBits() uint16 {
lengthInBits := uint16(0)
// Discriminator Field (errorFlag)
lengthInBits += 1
// Discriminator Field (functionFlag)
lengthInBits += 7
return lengthInBits
}
func (m *ModbusPDU) LengthInBytes() uint16 {
return m.LengthInBits() / 8
}
func ModbusPDUParse(readBuffer utils.ReadBuffer, response bool) (*ModbusPDU, error) {
if pullErr := readBuffer.PullContext("ModbusPDU"); pullErr != nil {
return nil, pullErr
}
// Discriminator Field (errorFlag) (Used as input to a switch field)
errorFlag, _errorFlagErr := readBuffer.ReadBit("errorFlag")
if _errorFlagErr != nil {
return nil, errors.Wrap(_errorFlagErr, "Error parsing 'errorFlag' field")
}
// Discriminator Field (functionFlag) (Used as input to a switch field)
functionFlag, _functionFlagErr := readBuffer.ReadUint8("functionFlag", 7)
if _functionFlagErr != nil {
return nil, errors.Wrap(_functionFlagErr, "Error parsing 'functionFlag' field")
}
// Switch Field (Depending on the discriminator values, passes the instantiation to a sub-type)
var _parent *ModbusPDU
var typeSwitchError error
switch {
case errorFlag == true: // ModbusPDUError
_parent, typeSwitchError = ModbusPDUErrorParse(readBuffer)
case errorFlag == false && functionFlag == 0x02 && response == false: // ModbusPDUReadDiscreteInputsRequest
_parent, typeSwitchError = ModbusPDUReadDiscreteInputsRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x02 && response == true: // ModbusPDUReadDiscreteInputsResponse
_parent, typeSwitchError = ModbusPDUReadDiscreteInputsResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x01 && response == false: // ModbusPDUReadCoilsRequest
_parent, typeSwitchError = ModbusPDUReadCoilsRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x01 && response == true: // ModbusPDUReadCoilsResponse
_parent, typeSwitchError = ModbusPDUReadCoilsResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x05 && response == false: // ModbusPDUWriteSingleCoilRequest
_parent, typeSwitchError = ModbusPDUWriteSingleCoilRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x05 && response == true: // ModbusPDUWriteSingleCoilResponse
_parent, typeSwitchError = ModbusPDUWriteSingleCoilResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x0F && response == false: // ModbusPDUWriteMultipleCoilsRequest
_parent, typeSwitchError = ModbusPDUWriteMultipleCoilsRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x0F && response == true: // ModbusPDUWriteMultipleCoilsResponse
_parent, typeSwitchError = ModbusPDUWriteMultipleCoilsResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x04 && response == false: // ModbusPDUReadInputRegistersRequest
_parent, typeSwitchError = ModbusPDUReadInputRegistersRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x04 && response == true: // ModbusPDUReadInputRegistersResponse
_parent, typeSwitchError = ModbusPDUReadInputRegistersResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x03 && response == false: // ModbusPDUReadHoldingRegistersRequest
_parent, typeSwitchError = ModbusPDUReadHoldingRegistersRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x03 && response == true: // ModbusPDUReadHoldingRegistersResponse
_parent, typeSwitchError = ModbusPDUReadHoldingRegistersResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x06 && response == false: // ModbusPDUWriteSingleRegisterRequest
_parent, typeSwitchError = ModbusPDUWriteSingleRegisterRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x06 && response == true: // ModbusPDUWriteSingleRegisterResponse
_parent, typeSwitchError = ModbusPDUWriteSingleRegisterResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x10 && response == false: // ModbusPDUWriteMultipleHoldingRegistersRequest
_parent, typeSwitchError = ModbusPDUWriteMultipleHoldingRegistersRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x10 && response == true: // ModbusPDUWriteMultipleHoldingRegistersResponse
_parent, typeSwitchError = ModbusPDUWriteMultipleHoldingRegistersResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x17 && response == false: // ModbusPDUReadWriteMultipleHoldingRegistersRequest
_parent, typeSwitchError = ModbusPDUReadWriteMultipleHoldingRegistersRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x17 && response == true: // ModbusPDUReadWriteMultipleHoldingRegistersResponse
_parent, typeSwitchError = ModbusPDUReadWriteMultipleHoldingRegistersResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x16 && response == false: // ModbusPDUMaskWriteHoldingRegisterRequest
_parent, typeSwitchError = ModbusPDUMaskWriteHoldingRegisterRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x16 && response == true: // ModbusPDUMaskWriteHoldingRegisterResponse
_parent, typeSwitchError = ModbusPDUMaskWriteHoldingRegisterResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x18 && response == false: // ModbusPDUReadFifoQueueRequest
_parent, typeSwitchError = ModbusPDUReadFifoQueueRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x18 && response == true: // ModbusPDUReadFifoQueueResponse
_parent, typeSwitchError = ModbusPDUReadFifoQueueResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x14 && response == false: // ModbusPDUReadFileRecordRequest
_parent, typeSwitchError = ModbusPDUReadFileRecordRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x14 && response == true: // ModbusPDUReadFileRecordResponse
_parent, typeSwitchError = ModbusPDUReadFileRecordResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x15 && response == false: // ModbusPDUWriteFileRecordRequest
_parent, typeSwitchError = ModbusPDUWriteFileRecordRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x15 && response == true: // ModbusPDUWriteFileRecordResponse
_parent, typeSwitchError = ModbusPDUWriteFileRecordResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x07 && response == false: // ModbusPDUReadExceptionStatusRequest
_parent, typeSwitchError = ModbusPDUReadExceptionStatusRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x07 && response == true: // ModbusPDUReadExceptionStatusResponse
_parent, typeSwitchError = ModbusPDUReadExceptionStatusResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x08 && response == false: // ModbusPDUDiagnosticRequest
_parent, typeSwitchError = ModbusPDUDiagnosticRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x08 && response == true: // ModbusPDUDiagnosticResponse
_parent, typeSwitchError = ModbusPDUDiagnosticResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x0B && response == false: // ModbusPDUGetComEventCounterRequest
_parent, typeSwitchError = ModbusPDUGetComEventCounterRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x0B && response == true: // ModbusPDUGetComEventCounterResponse
_parent, typeSwitchError = ModbusPDUGetComEventCounterResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x0C && response == false: // ModbusPDUGetComEventLogRequest
_parent, typeSwitchError = ModbusPDUGetComEventLogRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x0C && response == true: // ModbusPDUGetComEventLogResponse
_parent, typeSwitchError = ModbusPDUGetComEventLogResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x11 && response == false: // ModbusPDUReportServerIdRequest
_parent, typeSwitchError = ModbusPDUReportServerIdRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x11 && response == true: // ModbusPDUReportServerIdResponse
_parent, typeSwitchError = ModbusPDUReportServerIdResponseParse(readBuffer)
case errorFlag == false && functionFlag == 0x2B && response == false: // ModbusPDUReadDeviceIdentificationRequest
_parent, typeSwitchError = ModbusPDUReadDeviceIdentificationRequestParse(readBuffer)
case errorFlag == false && functionFlag == 0x2B && response == true: // ModbusPDUReadDeviceIdentificationResponse
_parent, typeSwitchError = ModbusPDUReadDeviceIdentificationResponseParse(readBuffer)
default:
// TODO: return actual type
typeSwitchError = errors.New("Unmapped type")
}
if typeSwitchError != nil {
return nil, errors.Wrap(typeSwitchError, "Error parsing sub-type for type-switch.")
}
if closeErr := readBuffer.CloseContext("ModbusPDU"); closeErr != nil {
return nil, closeErr
}
// Finish initializing
_parent.Child.InitializeParent(_parent)
return _parent, nil
}
func (m *ModbusPDU) Serialize(writeBuffer utils.WriteBuffer) error {
return m.Child.Serialize(writeBuffer)
}
func (m *ModbusPDU) SerializeParent(writeBuffer utils.WriteBuffer, child IModbusPDU, serializeChildFunction func() error) error {
if pushErr := writeBuffer.PushContext("ModbusPDU"); pushErr != nil {
return pushErr
}
// Discriminator Field (errorFlag) (Used as input to a switch field)
errorFlag := bool(child.ErrorFlag())
_errorFlagErr := writeBuffer.WriteBit("errorFlag", (errorFlag))
if _errorFlagErr != nil {
return errors.Wrap(_errorFlagErr, "Error serializing 'errorFlag' field")
}
// Discriminator Field (functionFlag) (Used as input to a switch field)
functionFlag := uint8(child.FunctionFlag())
_functionFlagErr := writeBuffer.WriteUint8("functionFlag", 7, (functionFlag))
if _functionFlagErr != nil {
return errors.Wrap(_functionFlagErr, "Error serializing 'functionFlag' field")
}
// Switch field (Depending on the discriminator values, passes the serialization to a sub-type)
_typeSwitchErr := serializeChildFunction()
if _typeSwitchErr != nil {
return errors.Wrap(_typeSwitchErr, "Error serializing sub-type field")
}
if popErr := writeBuffer.PopContext("ModbusPDU"); popErr != nil {
return popErr
}
return nil
}
func (m *ModbusPDU) String() string {
if m == nil {
return "<nil>"
}
buffer := utils.NewBoxedWriteBufferWithOptions(true, true)
m.Serialize(buffer)
return buffer.GetBox().String()
}