| * Licensed to the Apache Software Foundation (ASF) under one |
| * or more contributor license agreements. See the NOTICE file |
| * distributed with this work for additional information |
| * regarding copyright ownership. The ASF licenses this file |
| * to you under the Apache License, Version 2.0 (the |
| * "License"); you may not use this file except in compliance |
| * with the License. You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, |
| * software distributed under the License is distributed on an |
| * "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY |
| * KIND, either express or implied. See the License for the |
| * specific language governing permissions and limitations |
| * under the License. |
| */ |
| |
| /** |
| * @file battery.h |
| * @brief Battery property |
| * |
| * The Batter property provides software view to data provided by fuel gauge |
| * ADC or charge controllers. |
| */ |
| |
| #ifndef __BATTERY_PROP_H__ |
| #define __BATTERY_PROP_H__ |
| |
| #include "os/mynewt.h" |
| |
| #ifdef __cplusplus |
| extern "C" { |
| #endif |
| |
| #if MYNEWT_VAL(BATTERY_MAX_PROPERTY_COUNT) |
| #define BATTERY_MAX_PROPERTY_COUNT MYNEWT_VAL(BATTERY_MAX_PROPERTY_COUNT) |
| #else |
| #define BATTERY_MAX_PROPERTY_COUNT 32 |
| #endif |
| |
| #define BATTERY_PROPERTY_MASK_SIZE (((BATTERY_MAX_PROPERTY_COUNT) + 31) / 32) |
| |
| /* Forward declaration of battery structure. */ |
| struct battery; |
| struct battery_property; |
| struct battery_prop_listener; |
| |
| /* Comments above intentionally not in Doxygen format */ |
| |
| /* ================================================================= |
| * ====================== DEFINES/MACROS =========================== |
| * ================================================================= |
| */ |
| |
| /** |
| * @{ Battery properties API |
| */ |
| |
| // ---------------------- TYPE ------------------------------------- |
| |
| typedef enum { |
| BATTERY_STATUS_UNKNOWN = 0, |
| /* Charger connected, battery charging */ |
| BATTERY_STATUS_CHARGING, |
| /* Charger not connected, battery discharging */ |
| BATTERY_STATUS_DISCHARGING, |
| /* Charger connected, not charging */ |
| BATTERY_STATUS_NOT_CHARGING, |
| /* Charger connected, not charging - battery full */ |
| BATTERY_STATUS_FULL, |
| } battery_status_t; |
| |
| typedef enum { |
| BATTERY_CAPACITY_LEVEL_UNKNOWN = 0, |
| BATTERY_CAPACITY_LEVEL_CRITICAL, |
| BATTERY_CAPACITY_LEVEL_LOW, |
| BATTERY_CAPACITY_LEVEL_NORMAL, |
| BATTERY_CAPACITY_LEVEL_HIGH, |
| BATTERY_CAPACITY_LEVEL_FULL, |
| } battery_capacity_level_t; |
| |
| typedef union battery_property_value { |
| float bpv_flt; |
| uint32_t bpv_u32; |
| int32_t bpv_i32; |
| uint16_t bpv_u16; |
| int16_t bpv_i16; |
| uint8_t bpv_u8; |
| int8_t bpv_i8; |
| /* in mV */ |
| int32_t bpv_voltage; |
| /* in mA */ |
| int32_t bpv_current; |
| /* in mAh */ |
| uint32_t bpv_capacity; |
| /* SOC in % 0..100 */ |
| uint8_t bpv_soc; |
| /* SOH in % 0..100 */ |
| uint8_t bpv_soh; |
| /* Temperature in deg C */ |
| float bpv_temperature; |
| /* Time in s */ |
| uint32_t bpv_time_in_s; |
| /* Number of charge cycles */ |
| uint16_t bpv_cycle_count; |
| battery_status_t bpv_status; |
| battery_capacity_level_t bpv_capacity_level; |
| uint8_t bpv_base_prop[4]; |
| } battery_property_value_t; |
| |
| /** |
| * Battery properties. |
| * Fuel gauge can exposes subset of those properties. |
| */ |
| typedef enum { |
| BATTERY_PROP_NONE, |
| /* Battery status supported */ |
| BATTERY_PROP_STATUS, |
| /* Battery capacity level supported */ |
| BATTERY_PROP_CAPACITY_LEVEL, |
| /* Battery capacity in mAh */ |
| BATTERY_PROP_CAPACITY, |
| /* Predicted full battery capacity in mAh */ |
| BATTERY_PROP_CAPACITY_FULL, |
| /* Current battery temperature in C */ |
| BATTERY_PROP_TEMP_NOW, |
| /* Ambient temperature in C */ |
| BATTERY_PROP_TEMP_AMBIENT, |
| /* Minimum voltage in V */ |
| BATTERY_PROP_VOLTAGE_MIN, |
| /* Maximum voltage in V */ |
| BATTERY_PROP_VOLTAGE_MAX, |
| /* Minimum designed voltage in V */ |
| BATTERY_PROP_VOLTAGE_MIN_DESIGN, |
| /* Maximum designed voltage in V */ |
| BATTERY_PROP_VOLTAGE_MAX_DESIGN, |
| /* Current voltage in V */ |
| BATTERY_PROP_VOLTAGE_NOW, |
| /* Current average voltage in V */ |
| BATTERY_PROP_VOLTAGE_AVG, |
| /* Maximum current in mAh */ |
| BATTERY_PROP_CURRENT_MAX, |
| /* Current level at this time in mAh */ |
| BATTERY_PROP_CURRENT_NOW, |
| /* Average current level in mAh */ |
| BATTERY_PROP_CURRENT_AVG, |
| /* State-Of-Charge, current capacity 0-100 % */ |
| BATTERY_PROP_SOC, |
| /* State-Of-Health, current battery state of health 0-100 % */ |
| BATTERY_PROP_SOH, |
| /* Predicted time to complete discharge in seconds */ |
| BATTERY_PROP_TIME_TO_EMPTY_NOW, |
| /* Predicted time to full capacity when charging in seconds */ |
| BATTERY_PROP_TIME_TO_FULL_NOW, |
| /* Number of full discharge/charge cycles */ |
| BATTERY_PROP_CYCLE_COUNT, |
| } battery_property_type_t; |
| |
| typedef enum { |
| BATTERY_PROPERTY_FLAGS_NONE = 0, |
| /* Set or get refers to property value that sets the alarm when |
| * property value goes below specified value |
| */ |
| BATTERY_PROPERTY_FLAGS_LOW_ALARM_SET_THRESHOLD = 0x01, |
| /* Set or get refers to property value that sets the alarm when |
| * property value goes below specified value |
| */ |
| BATTERY_PROPERTY_FLAGS_LOW_ALARM_CLEAR_THRESHOLD = 0x02, |
| BATTERY_PROPERTY_FLAGS_LOW_ALARM = 0x03, |
| /* Set or get refers to property value that sets the alarm when |
| * property value goes above specified value |
| */ |
| BATTERY_PROPERTY_FLAGS_HIGH_ALARM_SET_THRESHOLD = 0x04, |
| /* Set or get refers to property value that clears the alarm when |
| * property value goes below specified value. |
| */ |
| BATTERY_PROPERTY_FLAGS_HIGH_ALARM_CLEAR_THRESHOLD = 0x08, |
| /* Property is not supported by hardware |
| * This is specially important for threshold levels, |
| * battery manager can create software only threshold levels. |
| */ |
| BATTERY_PROPERTY_FLAGS_HIGH_ALARM = 0x0C, |
| BATTERY_PROPERTY_FLAGS_ALARM_THREASH = 0x0F, |
| BATTERY_PROPERTY_FLAGS_ALARM = 0x10, |
| BATTERY_PROPERTY_FLAGS_DERIVED = 0x80, |
| /* Flag only needed for battery_mgr_get_property() function. |
| * When property is requested that is not supported by hardware |
| * it can be synthesized as software only and used for alarms |
| */ |
| BATTERY_PROPERTY_FLAGS_CREATE = 0x40, |
| } battery_property_flags_t; |
| |
| /** |
| * Battery driver property declaration struct |
| * |
| * Driver provides array of those to declare what kind of properties |
| * are supported. |
| */ |
| struct battery_driver_property |
| { |
| battery_property_type_t bdp_type; |
| battery_property_flags_t bdp_flags; |
| const char * bdp_name; |
| }; |
| |
| /** |
| * Battery property |
| * It has type that specifies property type it can also have |
| * BATTERY_PROPERY_NOT_HARDWARE bit set if property was created |
| * by battery manager not a driver. |
| * It can also have threshold bits set if property is one of |
| * the threshold values. |
| */ |
| struct battery_property { |
| battery_property_type_t bp_type; |
| battery_property_flags_t bp_flags; |
| /* Field managed by battery manager */ |
| /* Battery property number */ |
| uint8_t bp_prop_num; |
| /* Battery property number in driver property array */ |
| uint8_t bp_drv_prop_num; |
| /* Driver number, 1 based index */ |
| uint8_t bp_drv_num:2; |
| /* Battery number, 0 based index */ |
| uint8_t bp_bat_num:2; |
| uint8_t bp_comp:1; |
| uint8_t bp_base:1; |
| /* Value of property is valid */ |
| uint8_t bp_valid:1; |
| battery_property_value_t bp_value; |
| }; |
| |
| static inline int driver_property(const struct battery_property *prop) |
| { |
| return 0 == (prop->bp_flags & BATTERY_PROPERTY_FLAGS_DERIVED); |
| } |
| |
| int battery_prop_get_value(struct battery_property *prop); |
| |
| int battery_prop_get_value_float(struct battery_property *prop, float *value); |
| int battery_prop_get_value_uint8(struct battery_property *prop, uint8_t *val); |
| int battery_prop_get_value_int8(struct battery_property *prop, int8_t *val); |
| int battery_prop_get_value_uint16(struct battery_property *prop, uint16_t *val); |
| int battery_prop_get_value_int16(struct battery_property *prop, int16_t *val); |
| int battery_prop_get_value_uint32(struct battery_property *prop, uint32_t *val); |
| int battery_prop_get_value_int32(struct battery_property *prop, int32_t *val); |
| |
| int battery_prop_set_value_float(struct battery_property *prop, float value); |
| int battery_prop_set_value_uint8(struct battery_property *prop, uint8_t val); |
| int battery_prop_set_value_int8(struct battery_property *prop, int8_t val); |
| int battery_prop_set_value_uint16(struct battery_property *prop, uint16_t val); |
| int battery_prop_set_value_int16(struct battery_property *prop, int16_t val); |
| int battery_prop_set_value_uint32(struct battery_property *prop, uint32_t val); |
| int battery_prop_set_value_int32(struct battery_property *prop, int32_t val); |
| |
| /** |
| * Register a property change listener. This allows a calling application to |
| * receive callbacks when property changes. |
| * Same listener can be used for many properties. |
| * |
| * @param The listener to register |
| * @param The battery property to register a listener on |
| * |
| * @return 0 on success, non-zero error code on failure. |
| */ |
| int battery_prop_change_subscribe(struct battery_prop_listener *listener, |
| struct battery_property *prop); |
| |
| /** |
| * Unregister a property change listener. |
| * |
| * @param The listener to unregister |
| * @param The battery property to unregister a listener from |
| * if prop is NULL, listener is unregistered from all properties |
| * |
| * @return 0 on success, non-zero error code on failure. |
| */ |
| int battery_prop_change_unsubscribe(struct battery_prop_listener *listener, |
| struct battery_property *prop); |
| |
| /** |
| * Register a battery listener. This allows a calling application to |
| * receive callbacks when new data was read from fuel gauge. |
| * |
| * @param The battery property to register a listener on |
| * @param The listener to register |
| * |
| * @return 0 on success, non-zero error code on failure. |
| */ |
| int battery_prop_poll_subscribe(struct battery_prop_listener *listener, |
| struct battery_property *prop); |
| |
| /** |
| * Unregister a property read listener. |
| * |
| * @param The listener to unregister |
| * @param The battery property to unregister a listener from |
| * if prop is NULL, listener is unregistered from all properties |
| * |
| * @return 0 on success, non-zero error code on failure. |
| */ |
| int battery_prop_poll_unsubscribe(struct battery_prop_listener *listener, |
| struct battery_property *prop); |
| |
| typedef int (*battery_prop_read_t)(struct battery_prop_listener *listener, |
| const struct battery_property *prop); |
| |
| typedef int (*battery_prop_changed_t)(struct battery_prop_listener *listener, |
| const struct battery_property *prop); |
| |
| /** |
| * Listener structure which may be registered to battery properties. |
| * User bpl_prop_read function will be called for every property that |
| * this listener is register for just after data is received. |
| */ |
| struct battery_prop_listener { |
| /* |
| * Battery data handler function, called when data was read. |
| */ |
| battery_prop_read_t bpl_prop_read; |
| /* |
| * Property changed function |
| */ |
| battery_prop_changed_t bpl_prop_changed; |
| }; |
| |
| /** |
| * }@ |
| */ |
| |
| /* End Battery Manager API */ |
| |
| |
| /** |
| * @} |
| */ |
| |
| /* End Battery API */ |
| |
| #ifdef __cplusplus |
| } |
| #endif |
| |
| #endif /* __BATTERY_PROP_H__ */ |