blob: 89e8ed317611a8c0428c80d58ee431f3f3c063f9 [file] [log] [blame]
/*
* Licensed to the Apache Software Foundation (ASF) under one or more
* contributor license agreements. See the NOTICE file distributed with
* this work for additional information regarding copyright ownership.
* The ASF licenses this file to You under the Apache License, Version 2.0
* (the "License"); you may not use this file except in compliance with
* the License. You may obtain a copy of the License at
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software
* distributed under the License is distributed on an "AS IS" BASIS,
* WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
* See the License for the specific language governing permissions and
* limitations under the License.
*/
namespace Apache.Ignite.Examples.DataStructures
{
using System;
using System.Threading;
using Apache.Ignite.Core;
using Apache.Ignite.Core.DataStructures;
using Apache.Ignite.ExamplesDll.DataStructures;
/// <summary>
/// The example demonstrates the usage of the distributed atomic sequence data structure, which has functionality
/// similar to <see cref="Interlocked"/>, but provides cluster-wide atomicity guarantees.
/// <para />
/// 1) Set this class as startup object (Apache.Ignite.Examples project -> right-click -> Properties ->
/// Application -> Startup object);
/// 2) Start example (F5 or Ctrl+F5).
/// <para />
/// This example can be run with standalone Apache Ignite.NET node:
/// 1) Run %IGNITE_HOME%/platforms/dotnet/bin/Apache.Ignite.exe:
/// Apache.Ignite.exe -configFileName=platforms\dotnet\examples\apache.ignite.examples\app.config -assembly=[path_to_Apache.Ignite.ExamplesDll.dll]
/// 2) Start example.
/// </summary>
public static class AtomicSequenceExample
{
[STAThread]
public static void Main()
{
// See app.config: <atomicConfiguration atomicSequenceReserveSize="10" />
// Each node reserves 10 numbers to itself, so that 10 increments can be done locally,
// without communicating to other nodes. After that, another 10 elements are reserved.
using (var ignite = Ignition.StartFromApplicationConfiguration())
{
Console.WriteLine();
Console.WriteLine(">>> Atomic sequence example started.");
IAtomicSequence atomicSequence =
ignite.GetAtomicSequence(AtomicSequenceIncrementAction.AtomicSequenceName, 0, true);
Console.WriteLine(">>> Atomic sequence initial value: " + atomicSequence.Read());
// Broadcast an action that increments AtomicSequence a number of times.
ignite.GetCompute().Broadcast(new AtomicSequenceIncrementAction());
// Actual value will depend on number of participating nodes.
Console.WriteLine("\n>>> Atomic sequence current value: " + atomicSequence.Read());
}
Console.WriteLine("\n>>> Check output on all nodes.");
Console.WriteLine("\n>>> Example finished, press any key to exit ...");
Console.ReadKey();
}
}
}