| Host Citrix XenServer Installation |
| ---------------------------------- |
| |
| If you want to use the Citrix XenServer hypervisor to run guest virtual |
| machines, install XenServer 6.0 or XenServer 6.0.2 on the host(s) in |
| your cloud. For an initial installation, follow the steps below. If you |
| have previously installed XenServer and want to upgrade to another |
| version, see :ref:`upgrading-xenserver-version`. |
| |
| |
| System Requirements for XenServer Hosts |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| |
| - The host must be certified as compatible with one of the following. |
| See the Citrix Hardware Compatibility Guide: |
| `http://hcl.xensource.com <http://hcl.xensource.com>`_ |
| |
| - XenServer 5.6 SP2 |
| - XenServer 6.0 |
| - XenServer 6.0.2 |
| - XenServer 6.1.0 |
| - XenServer 6.2.0 |
| - XenServer 6.5.0 |
| |
| - You must re-install Citrix XenServer if you are going to re-use a |
| host from a previous install. |
| |
| - Must support HVM (Intel-VT or AMD-V enabled) |
| |
| - Be sure all the hotfixes provided by the hypervisor vendor are |
| applied. Track the release of hypervisor patches through your |
| hypervisor vendor’s support channel, and apply patches as soon as |
| possible after they are released. CloudStack will not track or notify |
| you of required hypervisor patches. It is essential that your hosts |
| are completely up to date with the provided hypervisor patches. The |
| hypervisor vendor is likely to refuse to support any system that is |
| not up to date with patches. |
| |
| - All hosts within a cluster must be homogeneous. The CPUs must be of |
| the same type, count, and feature flags. |
| |
| - Must support HVM (Intel-VT or AMD-V enabled in BIOS) |
| |
| - 64-bit x86 CPU (more cores results in better performance) |
| |
| - Hardware virtualization support required |
| |
| - 4 GB of memory |
| |
| - 36 GB of local disk |
| |
| - At least 1 NIC |
| |
| - Statically allocated IP Address |
| |
| - When you deploy CloudStack, the hypervisor host must not have any VMs |
| already running |
| |
| .. warning:: |
| The lack of up-to-date hotfixes can lead to data corruption and lost VMs. |
| |
| |
| XenServer Installation Steps |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| |
| #. From `https://www.citrix.com/English/ss/downloads/ |
| <https://www.citrix.com/English/ss/downloads/>`_, |
| download the appropriate version of XenServer for your CloudStack |
| version (see `"System Requirements for XenServer Hosts" |
| <#system-requirements-for-xenserver-hosts>`_). Install it using |
| the Citrix XenServer Installation Guide. |
| |
| Older Versions of XenServer: |
| |
| Note that you can download the most recent release of XenServer |
| without having a Citrix account. If you wish to download older |
| versions, you will need to create an account and look through the |
| download archives. |
| |
| |
| Configure XenServer dom0 Memory |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| |
| Configure the XenServer dom0 settings to allocate more memory to dom0. |
| This can enable XenServer to handle larger numbers of virtual machines. |
| We recommend 2940 MB of RAM for XenServer dom0. For instructions on how |
| to do this, see `http://support.citrix.com/article/CTX126531 |
| <http://support.citrix.com/article/CTX126531>`_. The article refers to |
| XenServer 5.6, but the same information applies to XenServer 6.0. |
| |
| |
| Username and Password |
| ~~~~~~~~~~~~~~~~~~~~~ |
| |
| All XenServers in a cluster must have the same username and password as |
| configured in CloudStack. |
| |
| |
| Time Synchronization |
| ~~~~~~~~~~~~~~~~~~~~ |
| |
| The host must be set to use NTP. All hosts in a pod must have the same |
| time. |
| |
| #. Install NTP. |
| |
| .. parsed-literal:: |
| |
| # yum install ntp |
| |
| #. Edit the NTP configuration file to point to your NTP server. |
| |
| .. parsed-literal:: |
| |
| # vi /etc/ntp.conf |
| |
| Add one or more server lines in this file with the names of the NTP |
| servers you want to use. For example: |
| |
| .. parsed-literal:: |
| |
| server 0.xenserver.pool.ntp.org |
| server 1.xenserver.pool.ntp.org |
| server 2.xenserver.pool.ntp.org |
| server 3.xenserver.pool.ntp.org |
| |
| #. Restart the NTP client. |
| |
| .. parsed-literal:: |
| |
| # service ntpd restart |
| |
| #. Make sure NTP will start again upon reboot. |
| |
| .. parsed-literal:: |
| |
| # chkconfig ntpd on |
| |
| |
| Install CloudStack XenServer Support Package (CSP) |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| |
| (Optional) |
| |
| To enable security groups, elastic load balancing, and elastic IP on |
| XenServer, download and install the CloudStack XenServer Support Package |
| (CSP). After installing XenServer, perform the following additional |
| steps on each XenServer host. |
| |
| **For XenServer 6.1:** |
| |
| CSP functionality is already present in XenServer 6.1 |
| |
| #. Run the below command |
| |
| .. parsed-literal:: |
| |
| xe-switch-network-backend bridge |
| |
| #. update sysctl.conf with the following |
| |
| .. parsed-literal:: |
| |
| net.bridge.bridge-nf-call-iptables = 1 |
| net.bridge.bridge-nf-call-ip6tables = 0 |
| net.bridge.bridge-nf-call-arptables = 1 |
| |
| $ sysctl -p /etc/sysctl.conf |
| |
| |
| **For XenServer 6.0.2, 6.0, 5.6 SP2:** |
| |
| #. Download the CSP software onto the XenServer host from one of the |
| following links: |
| |
| For XenServer 6.0.2: |
| |
| `http://download.cloud.com/releases/3.0.1/XS-6.0.2/xenserver-cloud-supp.tgz |
| <http://download.cloud.com/releases/3.0.1/XS-6.0.2/xenserver-cloud-supp.tgz>`_ |
| |
| For XenServer 5.6 SP2: |
| |
| `http://download.cloud.com/releases/2.2.0/xenserver-cloud-supp.tgz |
| <http://download.cloud.com/releases/2.2.0/xenserver-cloud-supp.tgz>`_ |
| |
| For XenServer 6.0: |
| |
| `http://download.cloud.com/releases/3.0/xenserver-cloud-supp.tgz |
| <http://download.cloud.com/releases/3.0/xenserver-cloud-supp.tgz>`_ |
| |
| |
| #. Extract the file: |
| |
| .. parsed-literal:: |
| |
| # tar xf xenserver-cloud-supp.tgz |
| |
| #. Run the following script: |
| |
| .. parsed-literal:: |
| |
| # xe-install-supplemental-pack xenserver-cloud-supp.iso |
| |
| #. If the XenServer host is part of a zone that uses basic networking, |
| disable Open vSwitch (OVS): |
| |
| .. parsed-literal:: |
| |
| # xe-switch-network-backend bridge |
| |
| Restart the host machine when prompted. |
| |
| The XenServer host is now ready to be added to CloudStack. |
| |
| |
| Primary Storage Setup for XenServer |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| |
| CloudStack natively supports NFS, iSCSI and local storage. If you are |
| using one of these storage types, there is no need to create the |
| XenServer Storage Repository ("SR"). |
| |
| If, however, you would like to use storage connected via some other |
| technology, such as FiberChannel, you must set up the SR yourself. To do |
| so, perform the following steps. If you have your hosts in a XenServer |
| pool, perform the steps on the master node. If you are working with a |
| single XenServer which is not part of a cluster, perform the steps on |
| that XenServer. |
| |
| #. Connect FiberChannel cable to all hosts in the cluster and to the |
| FiberChannel storage host. |
| |
| #. Rescan the SCSI bus. Either use the following command or use |
| XenCenter to perform an HBA rescan. |
| |
| .. parsed-literal:: |
| |
| # scsi-rescan |
| |
| #. Repeat step 2 on every host. |
| |
| #. Check to be sure you see the new SCSI disk. |
| |
| .. parsed-literal:: |
| |
| # ls /dev/disk/by-id/scsi-360a98000503365344e6f6177615a516b -l |
| |
| The output should look like this, although the specific file name |
| will be different (scsi-<scsiID>): |
| |
| .. parsed-literal:: |
| |
| lrwxrwxrwx 1 root root 9 Mar 16 13:47 |
| /dev/disk/by-id/scsi-360a98000503365344e6f6177615a516b -> ../../sdc |
| |
| #. Repeat step 4 on every host. |
| |
| #. On the storage server, run this command to get a unique ID for the |
| new SR. |
| |
| .. parsed-literal:: |
| |
| # uuidgen |
| |
| The output should look like this, although the specific ID will be |
| different: |
| |
| .. parsed-literal:: |
| |
| e6849e96-86c3-4f2c-8fcc-350cc711be3d |
| |
| #. Create the FiberChannel SR. In name-label, use the unique ID you just |
| generated. |
| |
| .. parsed-literal:: |
| |
| # xe sr-create type=lvmohba shared=true |
| device-config:SCSIid=360a98000503365344e6f6177615a516b |
| name-label="e6849e96-86c3-4f2c-8fcc-350cc711be3d" |
| |
| This command returns a unique ID for the SR, like the following |
| example (your ID will be different): |
| |
| .. parsed-literal:: |
| |
| 7a143820-e893-6c6a-236e-472da6ee66bf |
| |
| #. To create a human-readable description for the SR, use the following |
| command. In uuid, use the SR ID returned by the previous command. In |
| name-description, set whatever friendly text you prefer. |
| |
| .. parsed-literal:: |
| |
| # xe sr-param-set uuid=7a143820-e893-6c6a-236e-472da6ee66bf name-description="Fiber Channel storage repository" |
| |
| Make note of the values you will need when you add this storage to |
| CloudStack later (see `"Add Primary Storage" |
| <configuration.html#add-primary-storage>`_). In the Add Primary Storage |
| dialog, in Protocol, you will choose PreSetup. In SR Name-Label, you |
| will enter the name-label you set earlier (in this example, |
| e6849e96-86c3-4f2c-8fcc-350cc711be3d). |
| |
| #. (Optional) If you want to enable multipath I/O on a FiberChannel SAN, |
| refer to the documentation provided by the SAN vendor. |
| |
| |
| iSCSI Multipath Setup for XenServer (Optional) |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| |
| When setting up the storage repository on a Citrix XenServer, you can |
| enable multipath I/O, which uses redundant physical components to |
| provide greater reliability in the connection between the server and the |
| SAN. To enable multipathing, use a SAN solution that is supported for |
| Citrix servers and follow the procedures in Citrix documentation. The |
| following links provide a starting point: |
| |
| - `http://support.citrix.com/article/CTX118791 |
| <http://support.citrix.com/article/CTX118791>`_ |
| |
| - `http://support.citrix.com/article/CTX125403 |
| <http://support.citrix.com/article/CTX125403>`_ |
| |
| You can also ask your SAN vendor for advice about setting up your Citrix |
| repository for multipathing. |
| |
| Make note of the values you will need when you add this storage to the |
| CloudStack later (see `"Add Primary Storage" |
| <configuration.html#add-primary-storage>`_). In the Add Primary Storage |
| dialog, in Protocol, you will choose PreSetup. In SR Name-Label, you will |
| enter the same name used to create the SR. |
| |
| If you encounter difficulty, address the support team for the SAN |
| provided by your vendor. If they are not able to solve your issue, see |
| Contacting Support. |
| |
| |
| Physical Networking Setup for XenServer |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| |
| Once XenServer has been installed, you may need to do some additional |
| network configuration. At this point in the installation, you should |
| have a plan for what NICs the host will have and what traffic each NIC |
| will carry. The NICs should be cabled as necessary to implement your |
| plan. |
| |
| If you plan on using NIC bonding, the NICs on all hosts in the cluster |
| must be cabled exactly the same. For example, if eth0 is in the private |
| bond on one host in a cluster, then eth0 must be in the private bond on |
| all hosts in the cluster. |
| |
| The IP address assigned for the management network interface must be |
| static. It can be set on the host itself or obtained via static DHCP. |
| |
| CloudStack configures network traffic of various types to use different |
| NICs or bonds on the XenServer host. You can control this process and |
| provide input to the Management Server through the use of XenServer |
| network name labels. The name labels are placed on physical interfaces |
| or bonds and configured in CloudStack. In some simple cases the name |
| labels are not required. |
| |
| When configuring networks in a XenServer environment, network traffic |
| labels must be properly configured to ensure that the virtual interfaces |
| are created by CloudStack are bound to the correct physical device. The |
| name-label of the XenServer network must match the XenServer traffic |
| label specified while creating the CloudStack network. This is set by |
| running the following command: |
| |
| .. parsed-literal:: |
| |
| xe network-param-set uuid=<network id> name-label=<CloudStack traffic label> |
| |
| |
| Configuring Public Network with a Dedicated NIC for XenServer (Optional) |
| ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ |
| |
| CloudStack supports the use of a second NIC (or bonded pair of NICs, |
| described in :ref:`nic-bonding-for-xenserver`) for the public network. If |
| bonding is not used, the public network can be on any NIC and can be on |
| different NICs on the hosts in a cluster. For example, the public |
| network can be on eth0 on node A and eth1 on node B. However, the |
| XenServer name-label for the public network must be identical across all |
| hosts. The following examples set the network label to "cloud-public". |
| After the management server is installed and running you must configure |
| it with the name of the chosen network label (e.g. "cloud-public"); this |
| is discussed in `"Management Server Installation" |
| <installation.html#management-server-installation>`_. |
| |
| If you are using two NICs bonded together to create a public network, |
| see :ref:`nic-bonding-for-xenserver`. |
| |
| If you are using a single dedicated NIC to provide public network |
| access, follow this procedure on each new host that is added to |
| CloudStack before adding the host. |
| |
| #. Run xe network-list and find the public network. This is usually |
| attached to the NIC that is public. Once you find the network make |
| note of its UUID. Call this <UUID-Public>. |
| |
| #. Run the following command. |
| |
| .. parsed-literal:: |
| |
| # xe network-param-set name-label=cloud-public uuid=<UUID-Public> |
| |
| |
| Configuring Multiple Guest Networks for XenServer (Optional) |
| ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ |
| |
| CloudStack supports the use of multiple guest networks with the |
| XenServer hypervisor. Each network is assigned a name-label in |
| XenServer. For example, you might have two networks with the labels |
| "cloud-guest" and "cloud-guest2". After the management server is |
| installed and running, you must add the networks and use these labels so |
| that CloudStack is aware of the networks. |
| |
| Follow this procedure on each new host before adding the host to |
| CloudStack: |
| |
| #. Run xe network-list and find one of the guest networks. Once you find |
| the network make note of its UUID. Call this <UUID-Guest>. |
| |
| #. Run the following command, substituting your own name-label and uuid |
| values. |
| |
| .. parsed-literal:: |
| |
| # xe network-param-set name-label=<cloud-guestN> uuid=<UUID-Guest> |
| |
| #. Repeat these steps for each additional guest network, using a |
| different name-label and uuid each time. |
| |
| |
| Separate Storage Network for XenServer (Optional) |
| ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ |
| |
| You can optionally set up a separate storage network. This should be |
| done first on the host, before implementing the bonding steps below. |
| This can be done using one or two available NICs. With two NICs bonding |
| may be done as above. It is the administrator's responsibility to set up |
| a separate storage network. |
| |
| Give the storage network a different name-label than what will be given |
| for other networks. |
| |
| For the separate storage network to work correctly, it must be the only |
| interface that can ping the primary storage device's IP address. For |
| example, if eth0 is the management network NIC, ping -I eth0 <primary |
| storage device IP> must fail. In all deployments, secondary storage |
| devices must be pingable from the management network NIC or bond. If a |
| secondary storage device has been placed on the storage network, it must |
| also be pingable via the storage network NIC or bond on the hosts as |
| well. |
| |
| You can set up two separate storage networks as well. For example, if |
| you intend to implement iSCSI multipath, dedicate two non-bonded NICs to |
| multipath. Each of the two networks needs a unique name-label. |
| |
| If no bonding is done, the administrator must set up and name-label the |
| separate storage network on all hosts (masters and slaves). |
| |
| Here is an example to set up eth5 to access a storage network on |
| 172.16.0.0/24. |
| |
| .. parsed-literal:: |
| |
| # xe pif-list host-name-label='hostname' device=eth5 |
| uuid(RO): ab0d3dd4-5744-8fae-9693-a022c7a3471d |
| device ( RO): eth5 |
| #xe pif-reconfigure-ip DNS=172.16.3.3 gateway=172.16.0.1 IP=172.16.0.55 mode=static netmask=255.255.255.0 uuid=ab0d3dd4-5744-8fae-9693-a022c7a3471d |
| |
| |
| .. _nic-bonding-for-xenserver: |
| |
| NIC Bonding for XenServer (Optional) |
| ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ |
| |
| XenServer supports Source Level Balancing (SLB) NIC bonding. Two NICs |
| can be bonded together to carry public, private, and guest traffic, or |
| some combination of these. Separate storage networks are also possible. |
| Here are some example supported configurations: |
| |
| - 2 NICs on private, 2 NICs on public, 2 NICs on storage |
| |
| - 2 NICs on private, 1 NIC on public, storage uses management network |
| |
| - 2 NICs on private, 2 NICs on public, storage uses management network |
| |
| - 1 NIC for private, public, and storage |
| |
| All NIC bonding is optional. |
| |
| XenServer expects all nodes in a cluster will have the same network |
| cabling and same bonds implemented. In an installation the master will |
| be the first host that was added to the cluster and the slave hosts will |
| be all subsequent hosts added to the cluster. The bonds present on the |
| master set the expectation for hosts added to the cluster later. The |
| procedure to set up bonds on the master and slaves are different, and |
| are described below. There are several important implications of this: |
| |
| - You must set bonds on the first host added to a cluster. Then you |
| must use xe commands as below to establish the same bonds in the |
| second and subsequent hosts added to a cluster. |
| |
| - Slave hosts in a cluster must be cabled exactly the same as the |
| master. For example, if eth0 is in the private bond on the master, it |
| must be in the management network for added slave hosts. |
| |
| |
| Management Network Bonding |
| '''''''''''''''''''''''''' |
| |
| The administrator must bond the management network NICs prior to adding |
| the host to CloudStack. |
| |
| |
| Creating a Private Bond on the First Host in the Cluster |
| '''''''''''''''''''''''''''''''''''''''''''''''''''''''' |
| |
| Use the following steps to create a bond in XenServer. These steps |
| should be run on only the first host in a cluster. This example creates |
| the cloud-private network with two physical NICs (eth0 and eth1) bonded |
| into it. |
| |
| #. Find the physical NICs that you want to bond together. |
| |
| .. parsed-literal:: |
| |
| # xe pif-list host-name-label='hostname' device=eth0 |
| # xe pif-list host-name-label='hostname' device=eth1 |
| |
| These command shows the eth0 and eth1 NICs and their UUIDs. |
| Substitute the ethX devices of your choice. Call the UUID's returned |
| by the above command slave1-UUID and slave2-UUID. |
| |
| #. Create a new network for the bond. For example, a new network with |
| name "cloud-private". |
| |
| **This label is important. CloudStack looks for a network by a name |
| you configure. You must use the same name-label for all hosts in the |
| cloud for the management network.** |
| |
| .. parsed-literal:: |
| |
| # xe network-create name-label=cloud-private |
| # xe bond-create network-uuid=[uuid of cloud-private created above] |
| pif-uuids=[slave1-uuid],[slave2-uuid] |
| |
| Now you have a bonded pair that can be recognized by CloudStack as the |
| management network. |
| |
| |
| Public Network Bonding |
| '''''''''''''''''''''' |
| |
| Bonding can be implemented on a separate, public network. The |
| administrator is responsible for creating a bond for the public network |
| if that network will be bonded and will be separate from the management |
| network. |
| |
| |
| Creating a Public Bond on the First Host in the Cluster |
| ''''''''''''''''''''''''''''''''''''''''''''''''''''''' |
| |
| These steps should be run on only the first host in a cluster. This |
| example creates the cloud-public network with two physical NICs (eth2 |
| and eth3) bonded into it. |
| |
| #. Find the physical NICs that you want to bond together. |
| |
| .. parsed-literal:: |
| |
| # xe pif-list host-name-label='hostname' device=eth2 |
| # xe pif-list host-name-label='hostname' device=eth3 |
| |
| These command shows the eth2 and eth3 NICs and their UUIDs. |
| Substitute the ethX devices of your choice. Call the UUID's returned |
| by the above command slave1-UUID and slave2-UUID. |
| |
| #. Create a new network for the bond. For example, a new network with |
| name "cloud-public". |
| |
| **This label is important. CloudStack looks for a network by a name |
| you configure. You must use the same name-label for all hosts in the |
| cloud for the public network.** |
| |
| .. parsed-literal:: |
| |
| # xe network-create name-label=cloud-public |
| # xe bond-create network-uuid=[uuid of cloud-public created above] |
| pif-uuids=[slave1-uuid],[slave2-uuid] |
| |
| Now you have a bonded pair that can be recognized by CloudStack as the |
| public network. |
| |
| |
| Adding More Hosts to the Cluster |
| '''''''''''''''''''''''''''''''' |
| |
| With the bonds (if any) established on the master, you should add |
| additional, slave hosts. Run the following command for all additional |
| hosts to be added to the cluster. This will cause the host to join the |
| master in a single XenServer pool. |
| |
| .. parsed-literal:: |
| |
| # xe pool-join master-address=[master IP] master-username=root |
| master-password=[your password] |
| |
| |
| Complete the Bonding Setup Across the Cluster |
| ''''''''''''''''''''''''''''''''''''''''''''' |
| |
| With all hosts added to the pool, run the cloud-setup-bond script. This |
| script will complete the configuration and set up of the bonds across |
| all hosts in the cluster. |
| |
| #. Copy the script from the Management Server in |
| /usr/share/cloudstack-common/scripts/vm/hypervisor/xenserver/cloud-setup-bonding.sh |
| to the master host and ensure it is executable. |
| |
| #. Run the script: |
| |
| .. parsed-literal:: |
| |
| # ./cloud-setup-bonding.sh |
| |
| Now the bonds are set up and configured properly across the cluster. |
| |
| |
| .. _upgrading-xenserver-version: |
| |
| Upgrading XenServer Versions |
| ~~~~~~~~~~~~~~~~~~~~~~~~~~~~ |
| |
| This section tells how to upgrade XenServer software on CloudStack |
| hosts. The actual upgrade is described in XenServer documentation, but |
| there are some additional steps you must perform before and after the |
| upgrade. |
| |
| .. note:: |
| Be sure the hardware is certified compatible with the new version of |
| XenServer. |
| |
| To upgrade XenServer: |
| |
| #. Upgrade the database. On the Management Server node: |
| |
| #. Back up the database: |
| |
| .. parsed-literal:: |
| |
| # mysqldump --user=root --databases cloud > cloud.backup.sql |
| # mysqldump --user=root --databases cloud_usage > cloud_usage.backup.sql |
| |
| #. You might need to change the OS type settings for VMs running on |
| the upgraded hosts. |
| |
| - If you upgraded from XenServer 5.6 GA to XenServer 5.6 SP2, |
| change any VMs that have the OS type CentOS 5.5 (32-bit), |
| Oracle Enterprise Linux 5.5 (32-bit), or Red Hat Enterprise |
| Linux 5.5 (32-bit) to Other Linux (32-bit). Change any VMs that |
| have the 64-bit versions of these same OS types to Other Linux |
| (64-bit). |
| |
| - If you upgraded from XenServer 5.6 SP2 to XenServer 6.0.2, |
| change any VMs that have the OS type CentOS 5.6 (32-bit), |
| CentOS 5.7 (32-bit), Oracle Enterprise Linux 5.6 (32-bit), |
| Oracle Enterprise Linux 5.7 (32-bit), Red Hat Enterprise Linux |
| 5.6 (32-bit) , or Red Hat Enterprise Linux 5.7 (32-bit) to |
| Other Linux (32-bit). Change any VMs that have the 64-bit |
| versions of these same OS types to Other Linux (64-bit). |
| |
| - If you upgraded from XenServer 5.6 to XenServer 6.0.2, do all |
| of the above. |
| |
| #. Restart the Management Server and Usage Server. You only need to |
| do this once for all clusters. |
| |
| .. parsed-literal:: |
| |
| # service cloudstack-management start |
| # service cloudstack-usage start |
| |
| #. Disconnect the XenServer cluster from CloudStack. |
| |
| #. Log in to the CloudStack UI as root. |
| |
| #. Navigate to the XenServer cluster, and click Actions – Unmanage. |
| |
| #. Watch the cluster status until it shows Unmanaged. |
| |
| #. Log in to one of the hosts in the cluster, and run this command to |
| clean up the VLAN: |
| |
| .. parsed-literal:: |
| |
| # . /opt/xensource/bin/cloud-clean-vlan.sh |
| |
| #. Still logged in to the host, run the upgrade preparation script: |
| |
| .. parsed-literal:: |
| |
| # /opt/xensource/bin/cloud-prepare-upgrade.sh |
| |
| Troubleshooting: If you see the error "can't eject CD," log in to the |
| VM and umount the CD, then run the script again. |
| |
| #. Upgrade the XenServer software on all hosts in the cluster. Upgrade |
| the master first. |
| |
| #. Live migrate all VMs on this host to other hosts. See the |
| instructions for live migration in the Administrator's Guide. |
| |
| Troubleshooting: You might see the following error when you |
| migrate a VM: |
| |
| .. parsed-literal:: |
| |
| [root@xenserver-qa-2-49-4 ~]# xe vm-migrate live=true host=xenserver-qa-2-49-5 vm=i-2-8-VM |
| You attempted an operation on a VM which requires PV drivers to be installed but the drivers were not detected. |
| vm: b6cf79c8-02ee-050b-922f-49583d9f1a14 (i-2-8-VM) |
| |
| To solve this issue, run the following: |
| |
| .. parsed-literal:: |
| |
| # /opt/xensource/bin/make_migratable.sh b6cf79c8-02ee-050b-922f-49583d9f1a14 |
| |
| #. Reboot the host. |
| |
| #. Upgrade to the newer version of XenServer. Use the steps in |
| XenServer documentation. |
| |
| #. After the upgrade is complete, copy the following files from the |
| management server to this host, in the directory locations shown |
| below: |
| |
| .. cssclass:: table-striped table-bordered table-hover |
| |
| ================================================================================= ======================================= |
| Copy this Management Server file To this location on the XenServer host |
| ================================================================================= ======================================= |
| /usr/share/cloudstack-common/scripts/vm/hypervisor/xenserver/xenserver60/NFSSR.py /opt/xensource/sm/NFSSR.py |
| /usr/share/cloudstack-common/scripts/vm/hypervisor/xenserver/setupxenserver.sh /opt/xensource/bin/setupxenserver.sh |
| /usr/share/cloudstack-common/scripts/vm/hypervisor/xenserver/make\_migratable.sh /opt/xensource/bin/make\_migratable.sh |
| /usr/share/cloudstack-common/scripts/vm/hypervisor/xenserver/cloud-clean-vlan.sh /opt/xensource/bin/cloud-clean-vlan.sh |
| ================================================================================= ======================================= |
| |
| #. Run the following script: |
| |
| .. parsed-literal:: |
| |
| # /opt/xensource/bin/setupxenserver.sh |
| |
| Troubleshooting: If you see the following error message, you can |
| safely ignore it. |
| |
| .. parsed-literal:: |
| |
| mv: cannot stat `/etc/cron.daily/logrotate`: No such file or directory |
| |
| #. Plug in the storage repositories (physical block devices) to the |
| XenServer host: |
| |
| .. parsed-literal:: |
| |
| # for pbd in `xe pbd-list currently-attached=false| grep ^uuid | awk '{print $NF}'`; do xe pbd-plug uuid=$pbd ; done |
| |
| .. note:: |
| If you add a host to this XenServer pool, you need to migrate all VMs |
| on this host to other hosts, and eject this host from XenServer pool. |
| |
| #. Repeat these steps to upgrade every host in the cluster to the same |
| version of XenServer. |
| |
| #. Run the following command on one host in the XenServer cluster to |
| clean up the host tags: |
| |
| .. parsed-literal:: |
| |
| # for host in $(xe host-list | grep ^uuid | awk '{print $NF}') ; do xe host-param-clear uuid=$host param-name=tags; done; |
| |
| .. note:: |
| When copying and pasting a command, be sure the command has pasted as |
| a single line before executing. Some document viewers may introduce |
| unwanted line breaks in copied text. |
| |
| #. Reconnect the XenServer cluster to CloudStack. |
| |
| #. Log in to the CloudStack UI as root. |
| |
| #. Navigate to the XenServer cluster, and click Actions – Manage. |
| |
| #. Watch the status to see that all the hosts come up. |
| |
| #. After all hosts are up, run the following on one host in the cluster: |
| |
| .. parsed-literal:: |
| |
| # /opt/xensource/bin/cloud-clean-vlan.sh |