Windows test skip inventory

This inventory covers test declarations whose skip expression excludes Windows. It is a Phase 0 baseline, not permission to retain the skips indefinitely. Locations intentionally omit line numbers so unrelated edits do not invalidate the semantic inventory.

Classifications

  • windows-backend-gap: the product contract is relevant on Windows, but the Windows transport, process, crash, or sandbox evidence is missing.
  • portable-candidate: the behavior appears platform-neutral; remove the skip or document the concrete Windows blocker.
  • platform-contract: the test intentionally exercises a POSIX/macOS primitive with no direct Windows equivalent.

Summary

ClassificationCount
windows-backend-gap18
portable-candidate0
platform-contract35

Total Windows-excluded declarations: 53

Inventory

ClassificationTestSkip expression
platform-contractapps/desktop/scripts/dev-app-runtime.test.mjs the real probe survives a hostile bundle pathprocess.platform !== 'darwin'
platform-contractapps/desktop/src/main/__tests__/project-context-root.test.ts rejects a session cwd without read and traversal accessprocess.platform === 'win32' ? 'POSIX permissions are required to make the session cwd inaccessible' : process.getuid?.() === 0
platform-contractapps/desktop/src/main/__tests__/shell-env.test.ts imports the login PATH without importing application control variablesprocess.platform === 'win32'
platform-contractapps/desktop/src/main/__tests__/shell-env.test.ts keeps the inherited PATH and does not log shell stderr when capture failsprocess.platform === 'win32'
platform-contractapps/desktop/src/main/__tests__/shell-env.test.ts kills login-shell descendants when capture times outprocess.platform === 'win32'
platform-contractapps/desktop/src/main/__tests__/shell-env.test.ts bounds shell output instead of buffering until the global timeoutprocess.platform === 'win32'
windows-backend-gappackages/headless/src/__tests__/sandbox.test.ts copies portable workspace evidence while skipping process-local special filesprocess.platform === 'win32'
windows-backend-gappackages/runtime-host/src/__tests__/control-endpoint.test.ts runtime host control endpointprocess.platform === 'win32'
windows-backend-gappackages/runtime-host/src/__tests__/execution-inspect-uds.test.ts a live Host serves Interactive inspection over its real endpoint while retaining exclusive ownershipprocess.platform === 'win32' ? 'Windows execution Host startup lifecycle' : false
windows-backend-gappackages/runtime-host/src/__tests__/host-kernel.test.ts an automatic failed liveness check is connection-fatal and Client close stays localprocess.platform === 'win32'
windows-backend-gappackages/runtime-host/src/__tests__/host-kernel.test.ts bounded election does not launch a Candidate after handshake exhausts the deadlineprocess.platform === 'win32'
windows-backend-gappackages/runtime-host/src/__tests__/host-kernel.test.ts a non-reading Client overload is isolated to its connectionprocess.platform === 'win32'
windows-backend-gappackages/runtime-host/src/__tests__/host-kernel.test.ts reports one shutdown failure through close and closed while releasing ownershipprocess.platform === 'win32'
platform-contractpackages/runtime-host/src/__tests__/host-kernel.test.ts publishes private POSIX endpoint and registration permissionsprocess.platform === 'win32'
windows-backend-gappackages/runtime-host/src/__tests__/memory-two-client-uds.test.ts two UDS clients share one recoverable Memory authority across Host deathprocess.platform === 'win32' ? 'POSIX process death gate' : false
windows-backend-gappackages/runtime-host/src/__tests__/runtime-policy-coordinator.test.ts invalidates when a real published mutation loses its commit replyprocess.platform === 'win32'
windows-backend-gappackages/runtime-host/src/__tests__/runtime-resource-process.test.ts real Host Runtime Resource process lifecycleprocess.platform === 'win32'
windows-backend-gappackages/runtime-host/src/__tests__/runtime-resource-two-client-uds.test.ts a Host-owned PTY survives Desktop disconnect and transfers control to TUIprocess.platform === 'win32' ? 'POSIX UDS and shell integration' : false
windows-backend-gappackages/runtime-host/src/__tests__/session-catalog-two-client-uds.test.ts two Clients share stable Session creation, CAS configuration, and catalog continuityprocess.platform === 'win32' ? 'Windows SQLite shutdown lifecycle' : false
windows-backend-gappackages/runtime-host/src/__tests__/session-catalog-two-client-uds.test.ts stable Session creation survives response loss and Host restartprocess.platform === 'win32' ? 'Windows SQLite shutdown lifecycle' : false
windows-backend-gappackages/runtime-host/src/__tests__/session-revision-two-client-uds.test.ts two Clients share exact retryable Session branch and revision authorityprocess.platform === 'win32' ? 'Windows SQLite shutdown lifecycle' : false
windows-backend-gappackages/runtime-host/src/__tests__/skill-catalog-two-client-uds.test.ts two UDS clients converge on one lease-bound Skill catalog authorityprocess.platform === 'win32'
windows-backend-gappackages/runtime-host/src/__tests__/usage-pricing-client-correlation.test.ts fails the connection for a canonical response with mismatched ${mismatch.name}process.platform === 'win32'
windows-backend-gappackages/runtime-host/src/__tests__/usage-pricing-client-correlation.test.ts rejects local invalid input without poisoning transport and correlates a private canonical copyprocess.platform === 'win32'
windows-backend-gappackages/runtime-host/src/__tests__/usage-pricing-two-client-uds.test.ts two clients share usage projection and one revision-CAS pricing authorityprocess.platform === 'win32'
platform-contractpackages/runtime/src/__tests__/filesystem-worker-process-runner.test.ts filesystem worker rejects boundedly when a detached descendant retains stdoutprocess.platform === 'win32' ? 'POSIX detached process-group semantics required' : false
platform-contractpackages/runtime/src/__tests__/filesystem-worker-smoke.test.ts macOS filesystem worker smokeprocess.platform !== 'darwin'
platform-contractpackages/runtime/src/__tests__/shell-exec.test.ts bounds output drain after the root exits while a detached descendant retains stdoutprocess.platform === 'win32' ? 'POSIX detached process-group semantics required' : false
platform-contractpackages/runtime/src/__tests__/shell-run-manager.test.ts latches timeout when the root exits during POSIX process discoveryprocess.platform === 'win32' ? 'POSIX process discovery only' : false
platform-contractpackages/runtime/src/__tests__/shell-run-manager.test.ts preserves cancellation when timeout fires during POSIX process discoveryprocess.platform === 'win32' ? 'POSIX process discovery only' : false
platform-contractpackages/runtime/src/__tests__/shell-run-manager.test.ts ignores a Stop abort that occurs after another admitted Stop commits terminationprocess.platform === 'win32' ? 'Windows termination has no asynchronous POSIX snapshot window' : false
platform-contractpackages/runtime/src/__tests__/shell-run-manager.test.ts keeps a pipe task alive when Stop aborts during process-tree preparationprocess.platform === 'win32' ? 'Windows termination does not take a POSIX process snapshot' : false
platform-contractpackages/runtime/src/__tests__/shell-run-manager.test.ts keeps a PTY task controllable when Stop aborts during process-tree preparationprocess.platform === 'win32' ? 'Windows termination does not take a POSIX process snapshot' : false
platform-contractpackages/runtime/src/__tests__/shell-run-manager.test.ts settles after root exit when a detached descendant retains inherited stdoutprocess.platform === 'win32' ? 'POSIX detached process-group semantics required' : false
platform-contractpackages/runtime/src/__tests__/shell-run-manager.test.ts keeps the first committed lifecycle cause across Stop and timeout racesprocess.platform === 'win32' ? 'Windows tree termination has no graceful SIGTERM phase' : false
platform-contractpackages/runtime/src/__tests__/shell-run-manager.test.ts keeps SIGTERM final output and escalates an ignored SIGTERM without leaking slotsprocess.platform === 'win32' ? 'Windows tree termination has no graceful SIGTERM phase' : false
platform-contractpackages/storage/src/__tests__/managed-workspace-baseline.test.ts rejects an authority database whose file identity changes after registrationprocess.platform === 'win32' ? 'Windows cannot rename an open SQLite database to replace its file identity' : false
platform-contractpackages/storage/src/__tests__/managed-workspace-baseline.test.ts does not return an accepted baseline when runtime.sqlite is replaced after the initial root checkprocess.platform === 'win32' ? 'Windows cannot rename an open SQLite database during the verification race' : false
platform-contractpackages/storage/src/__tests__/managed-workspace-baseline.test.ts rejects a source tree containing a non-UTF-8 Git pathprocess.platform === 'win32'
platform-contractpackages/storage/src/__tests__/managed-workspace-owner.test.ts rejects execution when runtime.sqlite detaches from its canonical path after verificationprocess.platform === 'win32' ? 'Open SQLite files cannot be renamed reliably on Windows' : false
platform-contractpackages/storage/src/__tests__/pet-pack-store.test.ts detects sprite sheets redirected outside the installed packprocess.platform === 'win32' ? 'Windows file-symlink permissions are not guaranteed in CI' : false
platform-contractpackages/storage/src/__tests__/root-authority.test.ts preserves unexpected marker I/O failures at the public authority boundaryprocess.platform === 'win32' ? 'POSIX permissions are required to make the marker unreadable' : typeof process.getuid === 'function' && process.getuid() === 0
platform-contractpackages/storage/src/__tests__/root-authority.test.ts rejects FIFO marker paths without blocking root resolutionprocess.platform === 'win32'
platform-contractpackages/storage/src/__tests__/root-authority.test.ts rejects a lock path that aliases another filesystem objectprocess.platform === 'win32' ? 'Windows file-symlink permissions are not guaranteed in CI' : false
platform-contractpackages/storage/src/__tests__/root-authority.test.ts validates an existing control directory without repairing its permissionsprocess.platform === 'win32'
platform-contractpackages/storage/src/__tests__/runtime-policy-stores.test.ts reports unknown outcome when credential persistence fails after clearing verified stateprocess.platform === 'win32' ? 'POSIX permissions are required to inject a persistence failure' : false
platform-contractpackages/storage/src/__tests__/runtime-policy-stores.test.ts validates proxy policy mutations before clearing and reports failed follow-up commits as unknownprocess.platform === 'win32' ? 'POSIX permissions are required to inject a persistence failure' : false
platform-contractpackages/storage/src/__tests__/runtime-policy-stores.test.ts reports unknown outcome when active proxy password persistence fails after clearingprocess.platform === 'win32' ? 'POSIX permissions are required to inject a persistence failure' : false
platform-contractpackages/storage/src/__tests__/runtime-policy-stores.test.ts preserves unknown commit semantics and consumes the completion ticketprocess.platform === 'win32' ? 'POSIX permissions are required to inject a persistence failure' : false
platform-contractpackages/storage/src/__tests__/runtime-policy-stores.test.ts successor recovery removes credentials orphaned by an interrupted connection removalprocess.platform === 'win32' ? 'POSIX permissions are required to inject a persistence failure' : false
platform-contractpackages/storage/src/__tests__/runtime-policy-stores.test.ts fails closed on final symlinks, FIFOs, and oversized documents without changing bytesprocess.platform === 'win32'
platform-contractpackages/storage/src/__tests__/usage-stores.test.ts classifies a renamed or replaced live root as a draining persistence failureprocess.platform === 'win32' ? 'Windows does not permit renaming a directory with an open SQLite database' : false
platform-contractpackages/storage/src/__tests__/workspace-identity.test.ts an unmarked read-only workspace fails without leaving marker stateprocess.platform === 'win32' ? 'POSIX permissions are required to create a read-only workspace fixture' : false